A desktop UPS bridges a short outage for a CPAP; it does not carry a full night. A CPAP at ResMed’s published typical 56.1 W uses 56.1 W x 8 h = about 450 Wh, while the best-documented UPS here stores roughly 230 Wh. The APC BR1500MS2 ranks first on this list for pure sine wave output and a listed runtime figure, but read the medical note below before you buy anything.
Medical note. This guide compares specs and energy math. It is not medical advice, and no UPS here is sold as a medical backup. Ask your CPAP maker (ResMed, Philips) which backup power sources it supports, and ask your medical equipment supplier and doctor what arrangement fits your therapy. Copies of CyberPower’s manual for the CP1350PFCLCD and CP1500PFCLCD say not to use the unit for medical or life support equipment (we could not open the original on cyberpower.com), so we left CyberPower models off this list. Read the manual of any UPS you consider.
Quick Comparison
Estimated runtime is our calculation at 56.1 W, scaled from the listing’s 100 W figure as listing minutes x 100 / 56.1. Real runtime differs and does not scale in a straight line, so use the maker’s chart.
| Model | Max output | Output type (listing) | Listed runtime at 100 W | Rough runtime at 56.1 W | Best for |
|---|---|---|---|---|---|
| APC BR1500MS2 | 900 W | Pure sine wave | 73 min | about 2.2 h | Bridge a gap, replaceable battery |
| GOLDENMATE 1000VA/800W | 800 W | Pure sine wave | 230 Wh LiFePO4, no minutes given | about 3.5 h (230 x 0.85 / 56.1) | Longest estimated bridge |
| APC BR1350MS | 810 W | Pure sine wave | 54 min | about 1.6 h | Smaller footprint |
How We Chose
We kept UPS units with listed pure sine wave output and at least 600 W, dropped any whose manual excludes medical use, then ranked them on published runtime or battery size, output type, replaceable battery, and the maker’s medical-use wording where we could read it. Sources are listings, maker manuals, and ResMed and Philips documents; the Yard & Grid Score comes from verified buyer ratings. We research and compare; we do not use or review the products ourselves. See how we choose.
The CPAP Load and the Runtime Math
The ResMed AirSense 11 user guide lists 56.1 W (111.5 VA) typical and 73.2 W (137.6 VA) peak. Every unit above is rated far higher, so the question is runtime, not capacity. Your machine, pressure, and humidifier settings change the draw; measure yours with a plug-in watt meter.
- One night: 56.1 W x 8 h = about 450 Wh, or 450 / 0.85 = about 530 Wh of battery (0.85 is a common planning figure for inverter loss).
- APC BR1500MS2 at 100 W for 73 min delivers 100 x (73 / 60) = about 122 Wh, so a night needs about 4 times that: 450 / 122 = 3.7.
- GOLDENMATE: 230 Wh x 0.85 = about 195 Wh, / 56.1 W = about 3.5 h, or 44 percent of a night.
For a whole night, makers sell batteries for the machine itself. ResMed lists its Power Station II (for AirSense 10 and S9, so check your model) at roughly 10 to 14 hours without the humidifier and heated tube, and about 2 to 3 hours with both. Philips lists a PAP Battery Kit with an integrated UPS for DreamStation and System One devices, up to 14 hours in CPAP mode at 10 cm H2O without heated humidification. Check the compatibility list for your exact device. For a larger option, see best power stations for CPAP and how long a power station runs a CPAP.
1. APC BR1500MS2
- 1500 VA / 900 W, pure sine wave, with a listed 73 min at 100 W and a user-replaceable battery (APCRBC163).
- The listing states a switchover of as little as 8 ms, and a three-year warranty.
- Lead-acid, 27.6 lb. We could not read a medical-use statement from APC; check the manual.
Best for: riding out a one-to-two-hour gap while you decide on a battery for the night.
Avoid if: you expect it to run a CPAP all night; the math above gives about 2.2 hours.
2. GOLDENMATE 1000VA/800W Lithium UPS
- The listing gives 230 Wh of LiFePO4 and pure sine wave output at 800 W.
- The listing claims more than 5,000 cycles and a 10-year life; we found no maker document to confirm either.
- Fan noise is stated below 50 dB; two-year warranty per the listing.
Best for: the longest estimated bridge, about 3.5 hours at 56.1 W.
Avoid if: you want a major-brand manual with a medical-use statement you can read.
3. APC BR1350MS
- 1350 VA / 810 W pure sine wave, 54 min at 100 W per the listing, replaceable battery (APCRBC161).
- About 96 minutes at 56.1 W by our scaling: 54 x 100 / 56.1.
- 25.7 lb, three-year warranty.
Best for: a bedside shelf where the BR1500MS2 is too deep.
Avoid if: you need more than about 1.5 hours.
Cost of Ownership
Lead-acid UPS batteries wear out, and APC’s manual says to replace the battery at least every 5 years. Listings show 3 to 5 years of average battery life. Budget for a replacement battery, and check the battery date before each storm season. Keep using the power supply that came with your CPAP, and ask the maker before using any other adapter.
How to Choose
- How long are your outages? Divide the unit’s Wh by your watts: 195 Wh / 56.1 W = about 3.5 h.
- What does your maker allow? Ask ResMed or Philips, then your supplier.
- Do you need a full night? Compare the maker battery or a power station in UPS mode; see UPS mode explained.
FAQ
Does a CPAP need a pure sine wave UPS?
We found no ResMed or Philips page requiring it in the sources we could read. Ask the maker or supplier; retailers commonly recommend it.
How long will a UPS run my CPAP?
Usually hours, not a night. Read how long a UPS lasts and use your own wattage.
Is a UPS a medical backup?
No. Ask your equipment supplier about backup power for your therapy.
Changelog: November 2026: first published.