Rated watt-hours x 0.85 / the load in watts = hours of runtime. A 1,024 Wh station running a steady 100 W load lasts about 1,024 x 0.85 / 100 = 8.7 hours, so plan on about 8.5, and the same station runs a 1,500 W load for only about 35 minutes.
Every number in that formula is printed somewhere you can read it: the capacity on the station’s spec sheet, the load on the device label or a plug-in watt meter. The 0.85 is the piece people skip, and it is why advertised runtimes and real ones disagree.
What Each Part of the Formula Means
- Rated Wh: the battery capacity in watt-hours, the size of the tank. If you are new to the unit, what a watt-hour is covers it in a few paragraphs.
- 0.85 inverter efficiency: a common planning figure for the energy lost turning battery DC into 120 V AC, plus the station’s own fans and display. Real conversion loss varies by model and load.
- Load watts: the average draw of what you plug in. For devices that cycle on and off, such as a fridge, use the average over a day, not the running or startup figure.
Runtime Table for Common Loads
Capacities are manufacturer ratings for the EcoFlow DELTA 3 Plus (1,024 Wh), the Jackery Explorer 1000 v2 (1,070 Wh), the EcoFlow DELTA 3 Max (2,048 Wh), and the EcoFlow DELTA 3 Ultra (3,072 Wh). The 56 W row is the typical power consumption ResMed publishes for the AirSense 11 CPAP; the other loads are round examples. Hours are rounded down.
| Load | 1,024 Wh (870 usable) | 1,070 Wh (910 usable) | 2,048 Wh (1,740 usable) | 3,072 Wh (2,610 usable) |
|---|---|---|---|---|
| 25 W (modem, router, one LED bulb) | about 34 h | about 36 h | about 69 h | about 104 h |
| 56 W (CPAP, ResMed typical figure) | about 15 h | about 16 h | about 31 h | about 46 h |
| 150 W (TV, laptop, lights) | about 5.5 h | about 6 h | about 11.5 h | about 17 h |
| 500 W (several mid-size devices at once) | about 1.7 h | about 1.8 h | about 3.4 h | about 5.2 h |
| 1,500 W (space heater on high) | about 35 min | about 36 min, at its 1,500 W limit | about 1 h 9 min | about 1 h 44 min |
Each cell is usable Wh / load W. For example, 1,740 Wh / 150 W = 11.6, rounded down to about 11.5 hours.
Three Household Examples
Apartment work-from-home day
A laptop averaging 45 W, a router at 10 W, and a 10 W desk lamp add to 65 W. On a 1,070 Wh station: 910 / 65 = about 14 hours, which covers a full workday and the evening. These device figures are examples; your laptop’s average is usually well below the number printed on its charger.
House with a fridge, evening outage
A 20 cu ft top-freezer at a 55 W planning average plus 30 W of lights is 85 W. On a 1,024 Wh station: 870 / 85 = about 10 hours. The fridge math is broken out in detail in how long a power station will run a fridge.
Mixed load with one big appliance
Big loads dominate the budget even when they run briefly. A 1,000 W coffee maker for 10 minutes uses 1,000 x (10 / 60) = about 167 Wh, the same energy as a 10 W router for almost 17 hours. Add each device’s watts x hours, total it, then divide the usable Wh by that total to see how many such days the station covers.
Why Real Runtime Comes In Lower
- Idle draw at light loads. An inverter switched on uses some power even with little plugged in, so a 10 W router on the AC outlet runs for less time than the formula says. Where a device can charge from USB-C or the 12 V port, the DC route skips the inverter.
- Cold rooms. Batteries deliver less in the cold, and most stations will not charge below freezing; see using a power station in cold weather.
- Battery age. Capacity fades with cycles. A station at 80 percent of original capacity gives 80 percent of the runtime in this table.
- Reserve settings. Many apps let you set a discharge floor or a backup reserve. A 10 percent floor removes 10 percent of usable energy.
Common Mistakes
- Dividing by the output rating. “1,500 W” on the box is how much the station can deliver at once, not a runtime figure.
- Using the device’s maximum instead of its average. A fridge or a CPAP with a heated humidifier swings up and down; the average is what drains the battery.
- Trusting marketing runtimes. Many brand charts skip inverter loss or assume a specific device setting. Rerun them with your own load.
To turn a runtime target into a station size, run the formula backward in how to choose the right size portable power station, then compare models in the best portable power stations for home backup.
FAQ
How long will a solar generator run?
“Solar generator” is a marketing name for a power station sold with panels, so the same formula applies to the battery. Solar adds energy during the day: 200 W of panels x 5 peak sun hours x 0.75 derate = about 750 Wh, which extends runtime by 750 / load W hours.
How long does a 1,000 Wh power station last?
About 850 / load W hours. At 50 W, that is about 17 hours; at 500 W, about 1.7 hours.
Does charging while running change the math?
Yes. If the station supports pass-through charging, the battery drains at load W minus charge W. When charge input exceeds the load, the battery fills instead of draining.
Changelog: November 2026: first published.