To convert a sprinkler zone to drip, add a filter and a pressure regulator that drops household pressure to about 20 to 30 psi, swap one spray head for a drip conversion body or kit, cap every other head on that zone, and run drip tubing from the converted head. The pipe and valve underground usually stay in place, and so does the backflow device that already protects your water supply.
What You Need Before You Cut Anything
| Part | What it does | Source note |
|---|---|---|
| Filter | Keeps grit out of small emitter openings | UC Master Gardeners of Sonoma County: conversion needs a filter to prevent emitter clogging |
| Pressure regulator | Cuts spray pressure to drip pressure, roughly 20 to 30 psi | Same UC guide |
| Conversion body, insert, or kit | Replaces a spray head and connects tubing; one per valve zone being converted | Sonoma Master Gardeners handout, Pub 121-001 |
| Caps | Seal the spray heads you are not using | Same handout |
| Risers (if needed) | Raise the converted body above new mulch | Same handout |
| Drip tubing, emitters, end caps | The new watering lines | See drip irrigation parts explained |
Some conversion bodies and kits have the filter and regulator built in. If yours does not, the Sonoma handout says to install them at the valve. Read the inlet and outlet pressure printed on the box before you buy, because kits differ.
Steps
- Shut off the water to the zone at the main sprinkler shutoff.
- Pick the head to convert, away from foot traffic and at a spot you can reach to clean the filter.
- Replace that spray insert or body with the conversion piece, and cap the remaining heads on the zone.
- Flush the line with the tubing end open before you close it, so dirt does not lodge in emitters (Arizona Extension notes new lines can hold debris from installation).
- Lay tubing and set emitters at each plant, then close the ends with caps or plugs.
- Run the zone and look for even flow at every emitter before you mulch.
You can often keep the existing controller and valve if the valve can handle the new total flow; confirm in the valve maker’s manual. Drip flow is very low, so also check the valve’s minimum flow rating, since some spray valves are not meant for tiny zones. This guide does not cover controller wiring; if the timer or valve needs electrical work, hire a licensed professional or follow the maker’s manual.
Backflow: Check Local Code
The International Plumbing Code model, as summarized by ICC, requires the potable water connection to an irrigation system to be protected from contamination, with devices such as vacuum breakers or reduced pressure assemblies. Your sprinkler system likely already has one. Leave it in place, and ask your water utility or building department whether a drip retrofit changes the device type or any required inspection. Rules vary by city and state.
Worked Example: Run Time
Say a converted zone waters a 100 sq ft bed that needs 1 inch a week. One inch over one square foot is 0.623 gallons, so the bed needs 100 x 0.623 = 62.3 gallons. With 40 one gallon per hour emitters, the zone puts out 40 x 1 = 40 gph, and the weekly run time is 62.3 / 40 = about 1.6 hours. Spread that over two or three mornings. The old spray zone ran in minutes, so reset the timer or you will under water.
Mistakes to Avoid
- Leaving spray heads uncapped, which dumps flow and drops pressure at the drip line.
- Skipping the regulator and blowing tubing off its barbs.
- Mixing lawn and drip plants on one zone. Turf needs far more water per week.
- Forgetting to winterize; see how to winterize a drip irrigation system.
Unsure whether drip suits your beds? Compare sprinkler vs drip irrigation. Starting from scratch instead of retrofitting? Use how to set up drip irrigation, or browse best drip irrigation kits. Method: how we choose.
Changelog: November 2026: first published.