Plan on about 0.5 to 1 kWh a day for a modern ENERGY STAR chest freezer, which is an average draw of roughly 22 to 40 watts. Current ENERGY STAR listings run from 196 kWh a year for a 5.1 cu ft model to 346 kWh a year for a 21.7 cu ft model: 196 kWh / 8,760 hours = about 22 W, and 346 kWh / 8,760 hours = about 39 W. While the compressor is actually running, the draw is higher, and for a split second at startup it is higher still.
Those three figures answer three separate backup questions. Average watts decide how big a battery you need, running watts decide the continuous output, and startup watts decide whether the compressor starts at all.
Five Real Chest Freezers, Run Through the Same Math
The annual kWh comes from each model’s ENERGY STAR listing. The running estimate borrows the Department of Energy rule of thumb for refrigerators, which says the compressor runs about one third of the time, so running watts are about average watts x 3. The startup column uses the 2 to 3 times multiplier power station makers commonly give for compressors, at the high end. Treat both as planning estimates, not measured values.
| Chest freezer (ENERGY STAR listing) | Size | Annual use | Federal maximum for its class | Per day (kWh / 365) | Average W (kWh x 1,000 / 8,760) | Est. running W (x 3) | Est. startup W (x 3 again) |
|---|---|---|---|---|---|---|---|
| Frigidaire FFCS0562AW | 5.1 cu ft | 196 kWh | 220 kWh | about 537 Wh | about 22 W | about 67 W | about 200 W |
| Midea MRC07M7AWW | 7.0 cu ft | 225 kWh | 251 kWh | about 616 Wh | about 26 W | about 77 W | about 230 W |
| Whirlpool WZC3209LW | 9.0 cu ft | 201 kWh | 224 kWh | about 551 Wh | about 23 W | about 69 W | about 205 W |
| GE FCM16DL | 15.7 cu ft | 277 kWh | 309 kWh | about 759 Wh | about 32 W | about 95 W | about 285 W |
| GE FCM22DL | 21.7 cu ft | 346 kWh | 386 kWh | about 948 Wh | about 39 W | about 118 W | about 355 W |
Two patterns stand out. Size matters less than you might expect: the 9.0 cu ft Whirlpool is listed below the 7.0 cu ft Midea, because the compact class and the full-size class have different federal limits and designs. And the federal maximum column shows what a non-ENERGY STAR freezer of the same size may use, about 11 to 12 percent more in each case. Older freezers can use more than either figure.
Find the Number for Your Own Freezer
- For energy (battery size): read the annual kWh on the yellow EnergyGuide label or look up the model in the ENERGY STAR product finder. Divide by 365 for kWh per day.
- For running watts: a plug-in energy meter between the freezer and the outlet shows the actual draw while the compressor runs. Without one, the x 3 estimate above is a reasonable starting point.
- For startup: plan on a power source whose surge rating clears at least three times the running estimate.
Worked Example: A Chest Freezer on a Power Station
Take the 15.7 cu ft GE FCM16DL and a 1,070 Wh station such as the Jackery Explorer 1000 v2, which Jackery rates at 1,500 W continuous and 3,000 W surge. Usable energy at the outlet is 1,070 Wh x 0.85 inverter efficiency, a common planning figure, = about 910 Wh. Runtime is 910 Wh / 32 W average = about 28 hours.
The output check passes with room to spare: about 95 W running and about 285 W at startup sit far below 1,500 W and 3,000 W. The battery is the limit, not the inverter. For the smallest model in the table, the same math gives 910 Wh / 22 W = about 41 hours; for the 21.7 cu ft GE, 910 Wh / 39 W = about 23 hours.
You may not need to run it nonstop. USDA guidance says a full freezer holds its temperature for about 48 hours with the lid closed, and a half-full one for about 24 hours. That makes a chest freezer one of the easiest loads to share: power it for a few hours, then move the station to the fridge.
Mistakes That Skew the Estimate
- Reading “15 amps” as the draw. Spec sheets often list a 15 A minimum circuit. That is the outlet circuit the freezer needs, 15 A x 120 V = 1,800 W of capacity, not what the freezer pulls.
- Ignoring where it sits. ENERGY STAR figures reflect standard room conditions. A freezer in a hot garage or an unheated porch can run longer than its label suggests; “garage ready” models are built for a wider temperature range.
- Sizing the inverter from the average. A 32 W average says nothing about the startup spike. Check surge rating separately.
- Leaving AC auto-off on. Some power stations switch the AC outlets off after a period of low draw. Between compressor cycles a freezer draws very little, so check the station’s settings before an outage.
For the fridge side of the same plan, see how many watts a refrigerator uses and how long a power station will run a fridge. The general formula lives in how long a portable power station will run, and the startup question in running watts vs starting watts. When you are ready to compare units, our best portable power stations for home backup guide ranks them for fridge-and-freezer plans.