Run a stored portable generator once a month for about 30 minutes with a load that includes a motor, such as a box fan. That is Generac’s recommendation for its portable units, and if a monthly run is not practical, Generac says to run it at least every three months for 30 minutes and use a fuel stabilizer.
The monthly run exercises the engine and the alternator, moves fresh fuel through the carburetor, and shows you a problem while there is still time to fix it, rather than during the first night of an outage. Your owner’s manual has the final word for your model.
Carbon Monoxide Rules Apply to Every Exercise Run
A 30-minute maintenance run produces the same carbon monoxide as a run during an outage. The CPSC says to operate portable generators outdoors only, at least 20 ft from the home, far from windows, doors, and vents, with the exhaust pointed away from the home, never in a garage, basement, or shed, and to keep CO alarms on every level and outside sleeping areas. Roll the generator out to its outage spot for each exercise run; do not run it in the garage doorway “just for a few minutes.” Follow the manufacturer’s instructions and local rules, and see how to run a generator safely for the full list.
A Maintenance Calendar
| When | Task | Source |
|---|---|---|
| Monthly | Run about 30 minutes with a motor load, such as a box fan | Generac |
| Every 3 months at minimum | Run 30 minutes if monthly runs are not practical; keep fuel stabilized | Generac |
| Whenever fuel will sit unused | Treat it with stabilizer, then run 30 minutes to circulate it | Generac |
| Within the first 30 hours | First oil change on most portable generators; smaller units may need it sooner | Generac |
| After that | Oil and service at the intervals in your manual | Your owner’s manual |
| Before long storage | Change oil; add 5 to 10 cc of oil or a fogging agent to the cylinder; stabilize or drain fuel | Generac |
Why the Load Matters
Generac specifically asks for a load that includes an appliance with a motor, so that both the engine and the alternator are exercised. Starting the generator and letting it idle with nothing plugged in confirms that it starts, but it does not show whether it holds voltage under a load.
Plug the load into the generator’s own outlets with an outdoor-rated extension cord. The CPSC says cords should be rated for outdoor use, have three prongs, and carry a rating above the total load. A box fan and a work light are plenty for an exercise run. Never plug a generator into a household outlet to power the house; connecting to home wiring requires a transfer switch or similar equipment installed by a licensed electrician.
Fuel: The Usual Reason a Generator Will Not Start
Gasoline goes stale faster than most owners expect. Generac says fuel stored more than 30 days without stabilizer can deteriorate and damage fuel system parts. Honda goes further: fuel problems can appear in less than 30 days, sometimes in as little as 15 depending on region, and Honda notes that stabilizer does not restore fuel that has already gone stale. Honda also limits its generators to fuel with no more than 10 percent ethanol.
Treated properly, fuel lasts much longer: Generac says adequately prepared fuel can be stored for up to 24 months. If fuel has not been stabilized, Generac says to drain it into an approved container before storage. The CPSC adds that fuel, including propane, should be stored outside living areas in labeled, non-glass containers, and that you should turn the generator off and let it cool before refueling.
What a Year of Exercise Runs Costs in Fuel
Very little. WEN lists the WEN DF480iX at 7 hours on its 1.9 gal tank at half load, which is 1.9 / 7 = about 0.27 gal per hour. Twelve 30-minute runs use 12 x 0.5 h x 0.27 = about 1.6 gal a year at half load, and less with a light fan load. That is a small price for knowing the engine starts and the carburetor is clean.
On propane, the same WEN lists 12 hours at half load on a 20 lb cylinder, so twelve 30-minute runs use 6 / 12 = half a cylinder a year. Fuel use at other loads is laid out in how much gas a generator uses.
Dual Fuel and Propane Generators
Propane does not go stale the way gasoline does; propane suppliers say the gas itself does not degrade and the cylinder’s condition is the limit. That makes propane attractive for exercise runs on a dual fuel unit. The catch: any gasoline left in the tank or carburetor still ages on its own schedule, so stabilize or drain the gasoline side as your manual directs, and check the manual for whether it wants periodic runs on both fuels. Background on the two fuels is in dual fuel generators explained and propane vs gas generators.
Example: A Generator Bought in October
Say you buy a dual fuel inverter generator before winter in a Midwest state. A schedule that follows the sources above:
- Break-in: run it under load per the manual, then change the oil before 30 hours of use.
- November to March: fill with stabilized gasoline and run 30 minutes on the first weekend of each month with a box fan plugged in, outdoors at the outage spot.
- April: decide on summer storage. Either keep monthly runs on stabilized fuel, or prepare it for storage: change the oil, treat or drain the fuel, and oil the cylinder.
- September: fresh fuel, a 30-minute run under load, and a check of the CO shutoff indicator and the battery on electric-start models.
Logging the date and run time on a card taped to the generator makes the hour-based oil interval easy to track.
Common Mistakes
- Starting it, then shutting it off after a minute. The engine never warms up and the alternator never carries a load.
- Running it in the garage with the door open. CO builds up in partly enclosed spaces; the 20 ft outdoor rule applies to short runs too.
- Topping up stale fuel with fresh fuel. Stabilizer and fresh gas do not reverse fuel that has already degraded.
- Ignoring a CO shutoff. If the generator shuts itself off for carbon monoxide, move it farther from the house and never bypass the sensor; see what a CO shutoff sensor does.
If your current generator is hard to keep running, our ranked list in the best inverter generators for home use notes fuel shutoff valves and CO sensors for each model.
FAQ
How long should I run my generator each month?
About 30 minutes with a motor load, per Generac. Your manual may set a different time; follow it where it differs.
Is it bad to let a generator sit for a year?
It is fine if it was prepared for storage: oil changed, fuel stabilized or drained, and the cylinder protected. A generator left with untreated gasoline for a year is a likely no-start.
Should I drain the carburetor or use stabilizer?
Generac’s storage steps treat the fuel with stabilizer and run the engine 30 minutes to circulate it, and they require draining fuel that was not treated. Some inverter generators, such as the WEN DF480iX, have a fuel shutoff that lets the engine use up the fuel in the carburetor before it stops; check whether your manual recommends it.