Table of Contents

4 sections 2 min read

Connecting batteries in series adds their voltages and keeps the amp-hours the same; connecting them in parallel keeps the voltage and adds the amp-hours. Either way the stored energy in watt-hours is the sum of all the batteries.

The Two Rules

ConnectionVoltageAmp-hoursExample with two 12 V, 100 Ah batteries
SeriesAddsStays the same24 V, 100 Ah = 2,400 Wh
ParallelStays the sameAdds12 V, 200 Ah = 2,400 Wh

Watt-hours are volts x amp-hours, so both layouts hold 24 x 100 = 12 x 200 = 2,400 Wh. What changes is which voltage the bank delivers and how current is shared. See what a watt-hour is for the conversion.

Why Anyone Chooses One

  • Series raises system voltage. Higher voltage carries the same watts at lower current: 2,000 W draws about 167 A at 12 V but about 83 A at 24 V (watts / volts, ignoring losses).
  • Parallel raises capacity and the current the bank can deliver, while keeping 12 V for 12 V gear. Battle Born’s manual says capacity and current limits are additive.
  • Both together make a series-parallel bank: four 12 V, 100 Ah batteries as two series pairs in parallel give 24 V, 200 Ah.

Limits Set by the Maker

The battery maker’s manual sets how many units can be joined. Battle Born allows wiring in series up to 48 V, with no limit in parallel, and states not to operate its battery in series or parallel with any other type of battery. Lead-acid makers publish their own limits. Matching the same model, age and state of charge in one bank is the usual guidance.

The inverter or charger must match the bank voltage. A 12 V inverter cannot run from a 24 V bank.

Safety

This page explains the concept only. Link cables, fusing and layout must follow the battery, inverter and charger manuals, and a fixed installation in a house or RV belongs to a licensed electrician. Series banks carry higher voltage and parallel banks can deliver very high current if shorted, so treat both with care.

For the runtime math on a bank, see how long a deep cycle battery runs an inverter, and for sizing to a load, how many amp-hours you need for boondocking.

Changelog: November 2026: first published.