MERV, or minimum efficiency reporting value, is a 1 to 16 score under the ASHRAE 52.2 standard that rates how well an HVAC air filter captures particles of different sizes; a higher number means the filter captures more of them. EPA recommends at least MERV 13, or the highest rating your system’s fan and filter slot can accommodate, when smoke is a concern.

What the numbers mean

EPA’s MERV table lists minimum average capture by particle size. Two rows matter most to homeowners.

Rating0.3 to 1.0 micron1.0 to 3.0 micron3.0 to 10.0 micron
MERV 11at least 20%at least 65%at least 85%
MERV 13at least 50%at least 85%at least 90%

Fine particles fall in the smallest column, which is where MERV 13 pulls ahead of MERV 11 (at least 50 vs at least 20 percent, per the EPA table). EPA’s table lists no capture figure for MERV 8 at 0.3 to 1.0 micron, so MERV 13 vs MERV 8 is a large step in fine particle capture.

Higher is not always better for your system

Denser media resists airflow. EPA’s wording is “as high a rating as your system fan and filter slot can accommodate,” and for wildfire smoke it says you may need to consult a professional HVAC technician. Check your air handler’s manual for the maximum recommended filter rating and thickness before switching. If the manual caps you at a lower MERV, follow the manual.

Using MERV 13 during smoke

  • EPA says to set the system fan to “On” rather than “Auto” so air keeps moving through the filter.
  • If your system has a fresh air intake, EPA suggests turning it off or closing it, or setting it to recirculate.
  • Plan to replace the filter more often than the manufacturer’s usual interval. Smoke loads it faster.

A worked check: a 20 x 25 x 1 inch filter swapped every 90 days is about 4 changes a year (365 / 90). If heavy smoke makes you change it every 45 days, that is about 8 a year (365 / 45), so budget double the filters for a smoky season. Our best furnace filters for wildfire smoke guide compares MERV 13 options by size.

MERV vs HEPA and CADR

HEPA is a separate standard: EPA describes it as capturing at least 99.97 percent of 0.30 micron particles, and it is not based on MERV. MERV rates HVAC filters in your ductwork. CADR rates how much air a portable cleaner delivers. The two work together, and our MERV 13 vs HEPA filters page covers when to use each. For filter swap timing, see how often to change an air purifier filter.

Changelog: November 2026: first published.