Replace the whole smoke alarm 10 years after its manufacturing date, which is not the same as the day you bought or mounted it. NFPA’s wording is that all smoke alarms must be replaced 10 years after their manufacturing date. The battery is a separate, shorter clock.
Two clocks: the unit and the battery
| What | When to replace | Source |
|---|---|---|
| Smoke alarm (whole unit) | 10 years after the manufacturing date | NFPA |
| Battery, replaceable type | When the alarm chirps once every 30 or 60 seconds; USFA also says to replace 9-volt batteries at least once a year | NFPA, USFA |
| Any alarm that keeps chirping after a fresh battery | Now, the unit has reached end of life | NFPA |
| Combination smoke/CO alarm | At its end-of-life signal or 10 years, whichever comes first | NFPA 72, as quoted by trade and city sources |
| Standalone CO alarm | Per the maker: First Alert says most last 5 to 7 years; Kidde lists 10 years for most models made since 2013 | Maker pages |
Find the manufacture date, then do the math
Take the alarm off its bracket and look for the manufacture date printed on the unit. The owner’s manual shows where it is on your model. Then:
Replace-by year = manufacture year + 10.
- Label reads March 2016: replace by March 2026. That alarm is overdue now.
- Label reads June 2019: replace by June 2029. Write it on a sticky label on the bracket or in your phone calendar.
- No readable date: treat the alarm as past due and replace it. NFPA’s rule is date-based, so a missing date gives you nothing to count from.
Shelf age counts too, since the clock starts at manufacture. If you buy a spare, read its date before you mount it.
Battery chirps are not the same as end of life
A single chirp every 30 or 60 seconds means the battery is low. Fit a new one. If chirping continues after that, NFPA says the alarm is at the end of its life and the unit must be replaced. Sound patterns differ by brand, so check the user guide or search your brand and model.
Some alarms use a sealed battery meant to last the life of the unit, so you replace the entire alarm instead of a battery. X-Sense describes its SC07 combo alarm this way. The combo comparison lists which models use sealed or replaceable batteries.
Plan a whole-house swap
Homes often get all their alarms at once, so they all expire in the same year. Read every unit’s date once, list them, and replace the oldest first. Six original alarms from a house finished in 2015 share one replace-by year (2015 + 10 = 2025), so they are all due together.
- Hardwired alarms: NFPA says only qualified electricians should install them. Ask the electrician which models are compatible with your interconnect system.
- Battery alarms: mount the new unit in the old position unless the placement guide shows a gap.
- Old units: pull the battery and ask your local waste authority or the manufacturer how to dispose of the alarm.
NFPA points out that working alarms matter: roughly 3 out of 5 fire deaths happen in homes with no smoke alarms or no working smoke alarms. For the monthly check that catches a dead unit between replacements, see how to check a smoke alarm.
Changelog: November 2026: first published.