Charge the battery to full, keep it somewhere above freezing, and disconnect every load before winter. Then check it on a schedule: about every 2 to 3 months for a sealed AGM or gel battery, every 2 to 4 weeks for a flooded one, per Discover Battery. A battery left discharged is the one that sulfates and, in hard cold, freezes.
Match the Routine to the Chemistry
| Step | Lead-acid (AGM, gel, flooded) | LiFePO4 |
|---|---|---|
| Before storage | Charge to 100%. Discover Battery says to fully charge before storing and again before use. | Battle Born says to bring the batteries to a full charge, then disconnect them. |
| Where | Cool and dry, protected from the elements. Heat speeds self-discharge. | Above freezing if possible, per Battle Born. |
| Disconnect | Remove loads and charger leads, or follow the maker’s manual. | Open the disconnect switch or remove the positive main cable, and switch off solar inputs and loads. |
| Recheck | AGM or gel: every 2 to 3 months. Flooded: every 2 to 4 weeks. | Battle Born gives no schedule; it lists 2 to 3% self-discharge a month. |
Do the Winter Math
Discover Battery lists AGM and gel self-discharge at 1 to 2% a month at 46°F, 3 to 4% at 68°F, and 5 to 6% at 86°F. A 68°F garage across a 5-month winter: 5 months x 3 to 4% = 15 to 20% lost, so a full battery ends near 80 to 85%.
Discover Battery says to give a stored battery a boost charge when it falls below 75%, or approximately 12.40 V on a 12 V battery. A cold shed helps here: at 46°F the same 5 months costs only 5 to 10%. The reverse risk is a discharged battery. Discover lists the electrolyte freezing point at -75°F fully charged and -10°F when discharged, and a frozen flooded battery is typically not recoverable.
Lithium Has One Extra Rule
Battle Born’s BB10012i manual lists 32°F as the lowest charging temperature for standard models, while its winterizing page says the battery management system blocks charging below 24°F internal temperature. Treat 32°F as the line: before topping off a LiFePO4 battery in winter, bring it indoors until it warms. Heated models are the exception, so read the manual for yours. A heated model should also have its heat-enable wire disconnected during storage. For why the battery manages itself this way, see what a battery management system does.
When you pull it out in spring, charge it before loading it. Discover Battery says to fully charge a lead-acid battery again before returning it to service, and to equalize a flooded one first. Check the voltage rest reading after the battery has sat off the charger for a few hours, so a surface charge does not fool you.
Mistakes That Cost a Battery
- Storing it discharged because it “wasn’t used much.”
- Leaving a small parasitic load, such as a monitor or inverter standby, connected all winter.
- Charging a flooded or AGM battery in a closed space. Discover Battery says to always charge in a ventilated area, because charging can release hydrogen.
- Putting a frozen lead-acid battery straight on a charger. Discover says to let it reach room temperature first.
Choosing between chemistries? See LiFePO4 vs lead-acid. A portable power station follows similar rules in how to store a portable power station and power station in cold weather. Our home backup power guide covers the larger setup.
Changelog: November 2026: first published.