For most owners of a J1772 car, a 32 A plug-in unit such as the bokman Level 1 and Level 2 charger is the flexible pick: on a 240 V outlet it gives 32 x 240 = 7.68 kW, and its included 5-15 adapter covers a plain household outlet at a much slower rate. What matters most is the outlet you plug into, and any new 240 V outlet is work for a licensed electrician.

Quick Comparison

ChargerMax ampsPower at 240 VPlug (listing)Cable (listing)Best for
bokman 32 A32 A, steps from 6 A7.68 kWNEMA 14-50P, 5-15 adapter included25 ftOne cord for home and visits
Grizzl-E (GR1)40 A, selectable down to 16 A9.6 kWNEMA 14-5024 ftBroad review base
ELEGRP 40 A40 A, 16 to 40 A steps9.6 kWNEMA 14-5025 ftTimer and long reach
Lectron 40 A40 A9.6 kWNEMA 14-5016 ftUL 2594 named in listing
EVDANCE 16 A16 A3.84 kWNEMA 6-20, 5-15 adapter25 ft7 lb, no 14-50 needed

How We Chose

We compared plug type, amperage steps, cable length, safety marks named in each listing, warranty, and the Yard & Grid Score from verified-buyer ratings (see how we choose). Specs come from retail listings, a weak source, so confirm them against the maker’s manual. We research and compare; we do not use or review the products ourselves. Power is volts x amps / 1,000.

bokman Level 1 and Level 2 (32 A)

  • Listing: 6 to 32 A selectable, 1 to 12 hour delay timer, 25 ft cable, ETL, IP65, -22°F to 130°F, no Wi-Fi or app.
  • A 15 A circuit carries 15 x 0.8 = 12 A continuously, so a 120 V outlet gives 12 x 120 = 1.44 kW.
  • Rated 4.7 from about 212 buyers. The listing text also mentions 40 A, but the title says 32 A, so confirm before ordering.

Best for: travelers and renters who meet both outlet types. Avoid if: you want a Wi-Fi app.

Grizzl-E Level 2 (GR1)

  • Listing: 40, 32, 24, or 16 A, 24 ft cable, IP67, built-in GFCI, UL certified.
  • Needs a 50 A circuit at 40 A (40 / 0.8), or a 40 A circuit if you step down to 32 A.
  • Rated 4.6 from about 3,450 buyers, the largest sample here.

Best for: a garage outlet you trust. Avoid if: you need a 120 V adapter built in.

ELEGRP Level 2 (40 A)

  • Listing: 16, 20, 24, 32, or 40 A, 1 to 12 hour delay, 25 ft cable, ETL, IP67, 13.2 lb.
  • Listed operating range is -21°F to 121°F, with a 2-year warranty.
  • Rated 4.5 from 96 buyers, a small sample.

Best for: off-peak timing on a long cord. Avoid if: you weigh review history heavily.

Lectron Level 2 (40 A)

  • Listing: 40 A, ETL certified to UL 2594, IP65, 2-year warranty.
  • The cable is 16 ft, and the listing says it is not 25 ft. The title also says “extension cord,” but Lectron’s own page lists 16 ft and no separate cord, so confirm what ships.
  • Rated 4.5 from 154 buyers.

Best for: buyers who want the standard named. Avoid if: your car sits far from the outlet.

EVDANCE Level 1 and 2 (16 A)

  • Listing: NEMA 6-20 plug for 16 A at 240 V, plus a 6-20 to 5-15 adapter for 12 A at 120 V; 25 ft, 7 lb, IP66, 1-year warranty.
  • The listing says it does not fit 14-50 outlets without a separate adapter. Its text gives 3.68 kW while its spec table and EVDANCE’s own page give 3.84 kW; 16 x 240 = 3.84 kW.
  • Rated 4.3 across 856 reviews.

Best for: homes with a 6-20 outlet. Avoid if: your only 240 V outlet is a 14-50.

Cost of Ownership

The unit is the smaller bill if you lack a 240 V outlet; the electrician’s quote usually decides the total. See what a home charger installation costs. Of the five listings, three name a warranty: 1 year for EVDANCE and 2 years for ELEGRP and Lectron.

How to Choose

  • Match the outlet. A 14-50 is the 4-prong range outlet; a dryer outlet is a 14-30. Match the plug to what is on the wall, not the other way around.
  • Size the circuit. The Department of Energy says the National Electrical Code treats EV charging as a continuous load, so the usual sizing is 125% of the charger’s amps, which is amps / 0.8: 16 A needs 20 A, 32 A needs 40 A, and 40 A needs 50 A.
  • Do the time math. To add 30 kWh: 30 / 1.44 = 20.8 hours at 120 V and 12 A, 30 / 3.84 = 7.8 hours at 16 A, 30 / 7.68 = 3.9 hours at 32 A, and 30 / 9.6 = 3.1 hours at 40 A, before charging losses. Your car’s onboard charger may cap the rate; see how to choose charger amperage.
  • Check the connector. Four listings name J1772 and the Grizzl-E listing says it fits all EVs and PHEVs sold in North America; Tesla owners need an adapter (see J1772 vs NACS).

Plug-In Safety

Plug only into an outlet in good condition that your electrician has confirmed suits a long, continuous load. The Department of Energy’s Alternative Fuels Data Center says a Level 1 outlet should sit on a dedicated branch circuit, and that permits may be required for new circuits. Follow the charger’s manual, and skip extension cords and stacked adapters unless the maker approves them; a May 1990 CPSC release on extension cords, which is general and not specific to EV chargers, says not to use one unless absolutely necessary. If a plug, cord, or outlet feels hot, stop and call a licensed electrician. We give no wiring steps; installing a 14-50 outlet is a licensed electrician’s job. Compare formats in portable vs wall charger and see the permit guide.

FAQ

Can a portable charger use a regular outlet?

Only with a 120 V adapter. Of these five, the bokman and EVDANCE listings include one; the other three list only a 240 V plug. At 12 A expect 1.44 kW, so roughly 21 hours for 30 kWh.

Is a 14-50 outlet the same as a dryer outlet?

No. A 14-50 is the 4-prong range type and a dryer uses a 14-30. Do not swap plugs or adapters on your own.

Do I need an electrician?

Only if you lack a suitable 240 V outlet, or want one checked. That work is for a licensed electrician.