Pick the amperage your car can actually accept and your driving needs, then size the circuit at amps x 1.25. For most daily commutes a 32 A charger (7.68 kW) is plenty; 48 A (11.52 kW) helps only if the car’s onboard charger takes it and the panel has room.
Amps, kW, and breaker size
Power in kW = amps x 240 / 1,000. EV charging counts as a continuous load under the National Electrical Code, as the Department of Energy’s Alternative Fuels Data Center notes, so the breaker is amps / 0.8, the same as amps x 1.25. Charger installation manuals pair breaker and current the same way: a 60 A breaker allows a 48 A charger, a 50 A breaker 40 A, a 40 A breaker 32 A. The hours and miles columns ignore charging losses, and miles assume 3 miles per kWh.
| Charger amps | Breaker (amps / 0.8) | Power | Hours to add 40 kWh | Miles per hour |
|---|---|---|---|---|
| 16 A | 20 A | 3.84 kW | 10.4 | about 12 |
| 24 A | 30 A | 5.76 kW | 6.9 | about 17 |
| 32 A | 40 A | 7.68 kW | 5.2 | about 23 |
| 40 A | 50 A | 9.6 kW | 4.2 | about 29 |
| 48 A | 60 A | 11.52 kW | 3.5 | about 35 |
Four checks, in order
1. The car’s limit
The onboard charger caps AC power. If the owner’s manual lists 7.2 kW, a 48 A wall unit still delivers 7.2 kW. Look up the maximum AC rate for your exact model and year before paying for more amps.
2. The amps your driving needs
Required kW = daily kWh / hours plugged in. Take 60 miles a day at 3 miles per kWh: 20 kWh, or 20 / 0.9 = 22.2 kWh from the wall with an assumed 90% efficiency. Parked 10 hours, that needs 2.22 kW, or 2,220 / 240 = 9.3 A. A 16 A unit covers it with room to spare, and a Level 1 cord at 1.44 kW does not. Our charging time guide has the same math for other mileages.
3. Panel headroom
A 48 A charger adds 11.52 kW of continuous load. Whether your service can carry that is a load calculation for a licensed electrician; some homes need a panel upgrade or a load management device first. We do not give wiring steps.
4. Outlet or hardwired
A plug-in charger on a NEMA 14-50 outlet can be limited below its circuit’s headroom, because some plug-in units cap their own current at 32 A even on a 50 A circuit. Check the unit’s manual. The tradeoffs are in NEMA 14-50 vs hardwired.
32 A or 48 A?
The 16 extra amps cut a 40 kWh refill from 5.2 hours to 3.5, and they push the circuit from 40 A to 60 A. Choose 48 A if you drive heavy daily miles, own two EVs, or expect a next car with a larger onboard charger. Otherwise 32 A on a 40 A circuit meets most overnight needs and is easier on the panel. Ask the electrician about the circuit for the car you may own later, because redoing wiring costs more than choosing well once. Cost context is in installation costs, and permit rules in the permit guide.
FAQ
Can I set a 48 A charger to a lower amperage?
Many units allow it, and some cars let you cap the rate too. Check the charger manual, then have the electrician size the circuit to the setting.
Does a higher-amp charger charge any car faster?
Only up to the car’s limit. The onboard charger sets the ceiling, so extra amps beyond it add nothing.
Does amperage change the cost per kWh?
No. It changes speed, not the energy price; see home charging cost.
Changelog: November 2026: first published.