Charge the battery to full, keep it somewhere above freezing, and disconnect every load before winter. Then check it on a schedule: about every 2 to 3 months for a sealed AGM or gel battery, every 2 to 4 weeks for a flooded one, per Discover Battery. A battery left discharged is the one that sulfates and, in hard cold, freezes.

Match the Routine to the Chemistry

StepLead-acid (AGM, gel, flooded)LiFePO4
Before storageCharge to 100%. Discover Battery says to fully charge before storing and again before use.Battle Born says to bring the batteries to a full charge, then disconnect them.
WhereCool and dry, protected from the elements. Heat speeds self-discharge.Above freezing if possible, per Battle Born.
DisconnectRemove loads and charger leads, or follow the maker’s manual.Open the disconnect switch or remove the positive main cable, and switch off solar inputs and loads.
RecheckAGM or gel: every 2 to 3 months. Flooded: every 2 to 4 weeks.Battle Born gives no schedule; it lists 2 to 3% self-discharge a month.

Do the Winter Math

Discover Battery lists AGM and gel self-discharge at 1 to 2% a month at 46°F, 3 to 4% at 68°F, and 5 to 6% at 86°F. A 68°F garage across a 5-month winter: 5 months x 3 to 4% = 15 to 20% lost, so a full battery ends near 80 to 85%.

Discover Battery says to give a stored battery a boost charge when it falls below 75%, or approximately 12.40 V on a 12 V battery. A cold shed helps here: at 46°F the same 5 months costs only 5 to 10%. The reverse risk is a discharged battery. Discover lists the electrolyte freezing point at -75°F fully charged and -10°F when discharged, and a frozen flooded battery is typically not recoverable.

Lithium Has One Extra Rule

Battle Born’s BB10012i manual lists 32°F as the lowest charging temperature for standard models, while its winterizing page says the battery management system blocks charging below 24°F internal temperature. Treat 32°F as the line: before topping off a LiFePO4 battery in winter, bring it indoors until it warms. Heated models are the exception, so read the manual for yours. A heated model should also have its heat-enable wire disconnected during storage. For why the battery manages itself this way, see what a battery management system does.

When you pull it out in spring, charge it before loading it. Discover Battery says to fully charge a lead-acid battery again before returning it to service, and to equalize a flooded one first. Check the voltage rest reading after the battery has sat off the charger for a few hours, so a surface charge does not fool you.

Mistakes That Cost a Battery

  • Storing it discharged because it “wasn’t used much.”
  • Leaving a small parasitic load, such as a monitor or inverter standby, connected all winter.
  • Charging a flooded or AGM battery in a closed space. Discover Battery says to always charge in a ventilated area, because charging can release hydrogen.
  • Putting a frozen lead-acid battery straight on a charger. Discover says to let it reach room temperature first.

Choosing between chemistries? See LiFePO4 vs lead-acid. A portable power station follows similar rules in how to store a portable power station and power station in cold weather. Our home backup power guide covers the larger setup.