Match the prep to how long it will sit. Once it will sit longer than about a month, the carburetor and fuel are what fail first, so the job is to treat or drain them, change the oil, and park the unit somewhere cool and dry. Your owner’s manual has the final word for your model.

Pick the Prep by Storage Time

Sits unused forWhat Honda says (EU1000i, EU2000i, EU3000i Handi)
1 to 2 monthsFull tank of fresh fuel with stabilizer; if you are adding stabilizer for the first time, run the engine outdoors 10 minutes so treated fuel reaches the whole system
2 to 12 monthsDrain the carburetor per the manual; close the fuel cap vent
More than 1 yearDrain the fuel tank and the carburetor per the manual

Honda’s reasoning: fuel in the small carburetor float bowl goes stale faster than the tank. Generac, for its portable units, gives a different path: treat the fuel and run the engine 30 minutes to circulate it, or drain untreated fuel before storage. Generac adds that adequately prepared fuel can be stored up to 24 months. Both are manufacturer instructions for their own models, so follow the one in your manual.

The Storage Steps

  1. Let it cool. Shut it off and wait. The CPSC says to let a generator cool before refueling, and the same logic applies before you cover it.
  2. Change the oil. Generac lists this as part of storage prep. The oil grades are in what oil a generator takes.
  3. Deal with the fuel. Stabilize it and circulate it, or drain it, per the table above. A stabilizer will not revive fuel that has already gone stale, and Honda notes that stabilizers have a shelf life too.
  4. Protect the cylinder. Generac says to add 5 to 10 cc of oil or a fogging agent to the cylinder. Use the procedure in your manual for how to reach the cylinder.
  5. Clean and cover. Wipe off dirt and debris and use a breathable cover. Do not seal a damp unit under plastic.
  6. Park it cool and dry, out of direct sunlight.

Where It Lives Matters

Honda says to store the unit and its fuel container in a cool, dry area, away from direct sunlight. Keep gasoline in a sealed container made for fuel, and the CPSC adds that fuel, including propane, should be stored outside living areas in labeled, non-glass containers. Check local fire code for how much gasoline you may keep at home.

Pick a spot you can wheel out without moving anything. Any fuel-burning generator must run outdoors only, at least 20 ft from the home and far from windows, doors, and vents, with the exhaust pointed away from the house, and you want CO alarms on every level and outside sleeping areas. The full rules are in how to run a generator safely.

Example: Garage Shelf Over the Winter

An inverter unit that will sit November to April is about five months, which lands in Honda’s 2 to 12 month tier: drain the carburetor and store it dry. A conventional unit that you plan to start monthly can skip the drain, since the monthly exercise run keeps fuel moving.

Common Mistakes

  • Storing it with a part-full tank and no stabilizer. Honda notes the air in a partly filled tank promotes fuel deterioration.
  • Adding stabilizer to old gas. It will not reconstitute stale fuel, per Honda.
  • Keeping a gas can in the house. The CPSC says fuel belongs outside living areas.

FAQ

Should I leave gas in the generator over winter?

Only if it is treated with stabilizer and circulated, per Generac; otherwise drain it. Honda goes further for storage beyond a year and says to drain both the tank and carburetor.

Can I store a generator in a shed?

Storing it there is fine if the shed is dry and the fuel is handled as above. Running it there is not: never run a generator in a shed, garage, or any enclosed space.

Do I need to disconnect anything?

On electric-start models, check the battery per the manual and keep it charged. Do not touch home wiring; any connection to a panel is a job for a licensed electrician.