A generator interlock kit is a mechanical plate or slide fitted to the cover of a home’s main electrical panel that physically blocks the main breaker and a dedicated generator breaker from being switched on at the same time, so a portable generator can feed the panel without ever connecting to utility lines. It works by position alone: with the main breaker on, the plate holds the generator breaker off, and the generator breaker can only be turned on after the main is off.

This explainer covers how the concept works and who handles it. It contains no installation steps. Fitting an interlock and its generator breaker is panel work for a licensed electrician, under a permit, and acceptance is up to your local inspector.

How an Interlock Works, in Concept

The interlock has two states. In normal mode, the main breaker is on and the generator breaker is locked off, so the house runs on utility power. In generator mode, the main breaker is off, which lets the plate slide and the generator breaker turn on; power then comes in from the outdoor generator inlet box and reaches whichever branch breakers you leave on.

The device has no electronics and does no sensing. It cannot start the generator, and it does not limit the load. You choose the circuits by switching branch breakers, which means you also carry the job of staying within the generator’s capacity.

Why It Exists: Stopping Backfeed

Backfeed is generator power flowing out of the house into utility lines. The CPSC warns that it puts utility workers and neighbors served by the same utility transformer at risk of electrocution. An interlock is designed to block backfeed through the panel mechanically, as long as it is the correct kit for that panel and nobody defeats it.

According to the IAEI, the electrical inspectors’ association, a panelboard interlock is treated as transfer equipment under NEC Section 702.5 when it is identified for use with that specific panel. Panelboards and their interlock accessories fall under UL 67, while standalone transfer switches are evaluated to UL 1008. Panel makers sell interlocks designed for their own panels, and third-party kits exist for many models. Whether a given kit is accepted is your inspector’s call.

The Load Math an Interlock Leaves to You

With an interlock, the whole panel is available, so the budget is set by the generator and its connection. A 30 A, 240 V generator breaker and inlet carry up to 30 A x 240 V = 7,200 W. A house that averages 1.23 kW (EIA’s figure of 10,791 kWh a year / 8,760 hours) fits easily on average, but peaks do not: a well pump, a furnace blower, and a fridge compressor starting together can exceed a mid-size generator’s starting watts.

The practical answer is a written load plan, which the electrician can help you draw up and post at the panel: which circuits belong on generator power and which stay off, sized against the generator’s running and starting watts. Our explainer on running watts vs starting watts shows how to total them, and what size generator you need walks through the worksheet.

Interlock Kit vs Transfer Switch

QuestionInterlock kitManual transfer switch
Circuits available on generatorAny breaker in the panelOnly the circuits wired to the switch
Who limits the loadYou, by switching breakersThe short circuit list does much of it
HardwarePlate on the panel cover plus a generator breakerSeparate switch or subpanel next to the main panel
StandardUL 67 (panelboard accessory)UL 1008
FitMust be identified for your exact panelIndependent of panel brand

Interlocks tend to cost less because there is less hardware, and they suit owners who want flexibility. A transfer switch suits households that want a fixed, short list of backup circuits and fewer decisions during an outage. Our full interlock kit vs transfer switch comparison and transfer switch basics go further. Home battery systems use their own automatic transfer equipment instead; see whole-home battery backup options.

An interlock changes nothing about carbon monoxide. A portable generator feeding the panel must run outdoors only, at least 20 feet from the home, far from windows, doors, and vents, with the exhaust pointed away from the home, per CPSC guidance. Keep battery-powered or battery-backup CO alarms on every level and outside sleeping areas, and follow the manufacturer’s manual and local rules.

Changelog: November 2026: first published.