A carbon monoxide detector lasts about 5 to 10 years, depending on the model: Kidde rates most of the CO alarms it has made since 2013 at 10 years, First Alert says most CO alarms last 5 to 7 years, and the CDC advises replacing a detector every 5 years or on the schedule the manufacturer gives. When the rated life runs out, the alarm itself must be replaced; a fresh battery does not reset it.

Why CO detectors expire

The sensor wears out. Most current home CO alarms use an electrochemical sensor, and its response weakens with age whether or not it ever sees carbon monoxide. That is why the life is counted in years from manufacture or activation, not in alarms sounded, and why NFPA’s alarm code says a CO alarm must be replaced when its end-of-life signal starts or when the manufacturer’s replacement date arrives.

Typical lifespans by source

SourceWhat it says
CDCReplace every 5 years or according to the manufacturer’s instructions
KiddeCO alarms made since 2013 have a 10-year life, except three listed models; alarms made before 2013 have a 7-year life
First AlertMost CO alarms last 5 to 7 years; check the manual for your model
NFPA 72Replace at the end-of-life signal or the manufacturer’s replacement date
CPSCCheck the product literature or the manufacturer for the recommended replacement age

The model’s own label wins over any general figure. Many alarms print a manufacture date and a “replace by” date on the back.

Do carbon monoxide detectors go bad? How to tell

Yes, and most current models announce it. Kidde describes its non-digital CO alarms giving a quick beep every 30 seconds with a flashing red light at end of life, and its 10-year sealed models giving two beeps every 30 seconds. First Alert lists five beeps every minute as an end-of-life signal and points owners to the manual for their model’s exact pattern.

Kidde is explicit about two points. Its alarms do not detect carbon monoxide once they are in end-of-life mode, and changing the battery will not stop the chirp. Some models let you hush the end-of-life signal for 3 days at a time, up to 30 days, which buys time to buy a replacement and nothing more.

Work out your replacement date

Replacement date = manufacture or activation date + rated life in years. Take the date from the back of the alarm and the rated life from the manual or the label.

  • An alarm made in March 2017 with a 7-year life: 2017 + 7 = March 2024. In October 2026 it is about two and a half years overdue.
  • A 10-year sealed alarm activated in June 2020: 2020 + 10 = June 2030.
  • No date you can read, and no record of when it went up: replace it rather than guess.

Write each alarm’s date on a list kept with your emergency supplies. Our home emergency kit guide is a good place to keep that note alongside spare batteries.

Alarm life vs battery life vs smoke alarm life

  • Battery life: on alarms with replaceable batteries, the battery runs out long before the sensor. The CDC suggests changing batteries each spring and fall. A low-battery chirp stops with a new battery; an end-of-life chirp does not.
  • Sealed 10-year alarms: the battery is sealed in for the alarm’s rated life, so the whole unit is replaced at once.
  • Smoke alarms: NFPA guidance is 10 years from the manufacture date. A combination smoke and CO alarm is replaced at whichever limit it reaches first.

When you replace an alarm, put the new one in the right spot: our guide on where to put a carbon monoxide detector covers placement. To compare current models and their rated lives, see the best carbon monoxide detectors.

Changelog: November 2026: first published.