A sump pump check valve is a one-way valve on the discharge pipe that lets water leave the pit and stops the water standing in the pipe from falling back in when the pump shuts off. Without it, the pump re-pumps the same water, cycles more often, and wears faster.

How much water comes back

Take a 1.5 inch discharge pipe with an inner diameter of about 1.6 inches. Area is 3.14 x 0.8 x 0.8 = about 2.0 square inches, so each foot of pipe holds 2.0 x 12 = about 24 cubic inches. At 231 cubic inches per gallon, that is roughly 0.1 gallon per foot. A 10 foot vertical run returns about 1 gallon to the pit every cycle if nothing holds it back. That is why a pump with no valve can seem to run all the time: see why does my sump pump keep running.

Swing vs spring types

TypeHow it closesTrade-off
Swing (flapper)Hinged flap drops shut when flow stopsInexpensive and common; can slam shut with a loud thunk when flow reverses
Spring-loaded (quiet)Spring pushes the flapper shut as the pump stopsQuieter, because it seals before flow reverses

Where it goes and what to check

  • Flow arrow points away from the pump, toward the outside discharge. A backward valve blocks the pump.
  • Mount it within reach, usually on the vertical pipe (some valves are also rated for horizontal runs; check the valve), and match the pipe size on the valve body (commonly 1-1/4 or 1-1/2 inch).
  • Some pump makers call for a small relief hole in the pipe below the valve to prevent an air lock. Zoeller’s installation manual, for example, calls for a hole of about 3/16 inch in the discharge pipe below the check valve and the pit cover, checked now and then for clogging. Other makers differ, and some pumps or valves vent themselves. Follow your pump manual, not a forum post.
  • Signs of a failing valve: the pump restarts soon after it stops, water weeps at the couplings, or the motor runs with little discharge.

Safety: Zoeller’s manual says to always disconnect the pump from its power source before handling it, so do that before you reach into the pit or loosen any coupling. Ready.gov’s flood guidance adds: do not touch electrical equipment if it is wet or if you are standing in water. If your pit floods, call a licensed plumber or electrician rather than working around live equipment.

A check valve does not stop sewer or storm backflow through floor drains; that is a different device. Valves also wear, so inspect yours when you service the pump, and see how long do sump pumps last. To confirm the pump itself is the right size, read what size sump pump do I need, then compare models in best sump pumps. We research and compare; we do not run our own product trials.