A water powered sump pump backup is a secondary pump that uses the pressure of your municipal water supply, instead of electricity or a battery, to empty the sump pit when the main pump fails or the power goes out. City water rushes through a narrow nozzle called a venturi, the fast stream creates suction that pulls sump water up a pickup pipe, and both streams leave the house together through the discharge line. It keeps running as long as the water main holds pressure, with no battery to wear out.

How it works, step by step

  1. The backup is set so its float rises only above the level where the primary pump switches on, so it stays idle in normal weather.
  2. If the water keeps rising, because the primary failed or lost power, the float opens a valve on a 3/4 in municipal water line.
  3. City water flows through the venturi nozzle, and the suction it creates draws sump water in through a foot valve.
  4. The mixed stream is pushed out through its own 1-1/2 in discharge pipe, per the Liberty SumpJet SJ10 spec sheet.
  5. When the pit drops, the float closes the valve and the flow of city water stops.

How much it pumps

Output depends on two numbers: your water pressure and the lift from the pit to the discharge. Liberty publishes this table for the SumpJet SJ10 series, with pressure measured at the inlet while the valve is open and water is flowing. That flowing pressure runs lower than the static number a gauge shows with every tap closed.

Inlet pressure (flowing)4 ft lift8 ft lift12 ft lift15 ft lift
20 psi660 GPH348 GPHNot listedNot listed
30 psi765 GPH540 GPH330 GPHNot listed
40 psi924 GPH750 GPH558 GPH432 GPH
60 psi1,185 GPH1,020 GPH912 GPH810 GPH

Compare that with how fast your pit fills. In our sump pump sizing guide, an 18 in pit that rises 4 in per minute in a storm takes in about 4.4 gallons per minute, or 4.4 x 60 = about 264 GPH. At 40 psi and 12 ft of lift, the SJ10 moves 558 GPH, so it stays ahead by 558 / 264 = about 2 times. At 20 psi and 8 ft, it moves 348 GPH, a margin of only about 1.3 times, and at higher lifts Liberty lists no figure at all.

How much city water it uses

Makers often describe their units as removing about 2 gallons of sump water per gallon of city water. The plumbing codes are more cautious. IAPMO’s 2012 Green Plumbing and Mechanical Code Supplement sets a floor of 1.4 gallons pumped to 10 ft of height per gallon used at 60 psi, and a 2014 ICC code change proposal, filed on behalf of Liberty Pumps, called the older 2 gallon figure “just a guess driven primarily from advertising.”

For every 1,000 gallons pulled out of the pit, a pump at the 1.4 floor uses 1,000 / 1.4 = about 714 gallons of city water, and a pump at 2 to 1 uses 1,000 / 2 = 500 gallons. To estimate the water bill, multiply the gallons used by your utility’s rate per 1,000 gallons, and remember that some utilities also bill sewer charges on metered water.

Pros and cons

ProsCons
No battery to charge, maintain, or replaceNeeds municipal water; a private well pump stops when the power does
Runs for the length of an outage while water pressure holdsUses drinking water to move groundwater
Few moving partsCode requires a backflow prevention device, which adds plumbing work
Small and light (Liberty lists the SJ10 at 6 lb)Output drops sharply at low pressure or high lift
Alarm models warn you when it runsBackup use only; the green plumbing codes above allow it only as an emergency backup

Code requirements and cost

Because the pump connects drinking water to a sump pit, backflow protection is the central rule. Liberty’s spec sheet states that under the UPC an approved reduced pressure zone (RPZ) backflow device is required, and the IAPMO supplement adds a battery alarm rated at least 85 dB at 10 ft. Requirements vary by city, so have a licensed plumber pull the permit and fit the device your water utility accepts.

Cost comes in three parts: the pump itself, which sits in the budget to mid-range tier; the installation, where the backflow device and a separate discharge line often cost more than the pump; and upkeep, since many utilities require backflow assemblies to be inspected and certified on a schedule. A battery backup trades those costs for a battery that wears out and has to be replaced. Our guide to battery backup sump pumps covers that side.

Who it suits

  • Good fit: homes on city water with strong pressure, a lift under about 12 ft, and long outages in the local storm history.
  • Avoid if: you are on a private well, your flowing pressure is below about 30 psi, or your pit fills faster than the table above shows for your lift.
  • Either way: put a water sensor next to the pit, so you know when the backup has kicked in. Our best water leak detectors guide lists models that alert your phone, and where to put water leak detectors shows the placement.

Changelog: November 2026: first published.