A winter storm kit has one job that a general emergency kit does not: carrying a cold house through an ice storm that can keep the power off for days. Build it in this order: a CO alarm with battery backup, light, an alert radio that wakes you for an overnight warning, stored power sized for the fridge rather than for heat, then blankets, a fire extinguisher, and water. A 1,024 Wh power station delivers about 870 Wh at the outlet (1,024 x 0.85), which runs a typical fridge for most of a day but an electric space heater for only about 35 minutes.
Each pick below covers one line of the winter lists from Ready.gov and the National Weather Service. The list runs in the order we would buy.
Quick Comparison
One row per kit group, in buying order. Figures come from the maker pages and listings named in How We Chose.
| Kit group | Our pick | Key figures | Winter job | Best for |
|---|---|---|---|---|
| CO alarm | Kidde KN-COB-DP2 Plug-in CO Alarm | 120 V plug-in, 2 AA backup, 85 dB at 10 ft, 10-year life | Keeps sensing when the outlet goes dead | Any home with gas heat, a fireplace, or a generator plan |
| Light | Lepro 1000LM Rechargeable LED Lantern | 1,000 lm max, 4,400 mAh, listing runtime up to 12 h on warm white | Lights a room through long winter evenings | One per occupied room |
| Alerts | Midland WR120B NOAA Weather Radio | SAME county coding, 25 locations, 90 dB siren, 3 AA backup | Sounds for a warning issued overnight | Ice storm and blizzard country |
| Stored power | EcoFlow DELTA 3 Classic | 1,024 Wh LFP, 1,800 W, 26.7 lb, charges at 32°F to 113°F | Fridge, phones, router, lantern recharges | A fridge plus small loads for about a day |
| Warmth | QIO CHUANG Mylar Blankets, 4-pack | 84 x 55 in each, 8.32 oz for the pack (listing) | Layer under blankets, line a cold car | Every bed and every car kit |
| Fire | Kidde Basic 110 Fire Extinguisher | 1-A:10-B:C, 3.9 lb, 6-year limited warranty | Small fires while the fire department is slowed by ice | Kitchen and near any heater in use |
| Water | Reliance Aqua-Tainer 7 Gallon | 7 gal rigid, spigot, about 58 lb full | Drinking water if pipes freeze or a well pump stops | Well homes and homes with exposed pipes |
How We Chose
We started from the agency lists, not from products. Ready.gov’s winter weather page asks for smoke alarms and carbon monoxide detectors with battery backups, supplies for staying home several days without power, and extra batteries for radios and flashlights. The National Weather Service’s winter preparation page adds a NOAA Weather Radio, first-aid supplies, a fire extinguisher, and food that needs no cooking. The table maps those lines to the picks.
| Agency line | Source | Covered by |
|---|---|---|
| CO detectors with battery backup, every level and outside sleeping areas | Ready.gov winter weather | Kidde KN-COB-DP2 |
| Flashlight and extra batteries | NWS, Ready.gov kit | Lepro lantern (rechargeable) |
| Battery NOAA Weather Radio | NWS, Ready.gov kit | Midland WR120B |
| Stay home several days without power | Ready.gov winter weather | EcoFlow DELTA 3 Classic, water, food |
| Sleeping bag or warm blanket for each person | Ready.gov kit, additional list | Mylar blankets layered with your own bedding |
| Fire extinguisher and smoke alarm | NWS, Ready.gov kit | Kidde Basic 110 |
| Water, one gallon per person per day | Ready.gov kit | Aqua-Tainer |
| First aid, food that needs no cooking, medicine | NWS, Ready.gov kit | A basic kit (water, food, first aid) |
- One pick per group, chosen for how well it works in a cold, dark house.
- Maker specs we could check, with listing-only figures labeled.
- Works without grid power, or keeps sensing when the grid drops.
- Yard & Grid Score from verified buyer ratings as a check on owner satisfaction. See How We Choose.
We research and compare; we do not run our own product trials. Sources include ready.gov, weather.gov, cpsc.gov, kidde.com, midlandusa.com, us.ecoflow.com, and the Amazon listings noted below.
The Picks, Group by Group
CO alarm: Kidde KN-COB-DP2 Plug-in Carbon Monoxide Alarm
Buy this first, because winter outages are when people bring fuel-burning heat into play. A plug-in alarm without backup goes silent the moment the power fails; this one switches to two AA batteries.
- Kidde lists 85 dB at 10 ft and a UL single station CO alarm listing.
- 10-year life with an end-of-life warning; Kidde notes units made before 2013 do not carry the 10-year life.
- Event memory flags whether CO reached 100 ppm or higher while you were away.
- Placement: CPSC asks for CO alarms on every level and outside sleeping areas. A two-story house with a basement needs at least 3.
Best for: homes with a gas furnace, gas water heater, fireplace, attached garage, or a plan to run a generator.
Avoid if: the only outlet near the bedrooms sits behind furniture or curtains; CPSC advises against covered spots, so pick a battery-only model for that location.
Light: Lepro 1000LM Rechargeable LED Lantern
Winter outages come with long nights, so plan light by the evening, not by the hour. The CDC recommends battery lights over candles, and a lantern lights a whole room where a flashlight lights a spot.
- The listing gives up to 12 hours on warm white (300 lm), 8 hours on daylight (700 lm), and 6.5 hours at the full 1,000 lm. Treat those as upper bounds.
- Energy on board: 4,400 mAh x 3.7 V nominal cell voltage = about 16 Wh, a common planning conversion for lithium cells.
- A 4-night outage with 5 lit hours a night is 4 x 5 = 20 hours. At the listed 12 hours per charge, that is 20 / 12 = about 2 charges at best. Plan on more: 300 lm for 12 hours from 16 Wh would need 300 x 12 / 16 = 225 lm per watt, above the 125 to 135 lm per watt the DOE gives for the best LED luminaires. Each recharge costs the power station only about 16 Wh.
- A USB output lets it top up a phone in a pinch (listing).
Best for: lighting a kitchen or living room each evening of a multi-day outage.
Avoid if: you need lights that turn on by themselves in a dark hallway; plug-in auto-on emergency lights do that job.
Alerts: Midland WR120B NOAA Weather Radio
Ice storms often arrive overnight, and a phone on silent will not wake you for a warning. Ready.gov says a Winter Storm Watch usually comes 12 to 48 hours ahead and a Warning 12 to 24 hours ahead; this radio sounds when one is issued for your county.
- SAME (Specific Area Message Encoding) lets you program up to 25 locations, so it alerts only for counties you choose, per Midland.
- 90 dB siren with selectable tone; Midland recommends the VOICE alert setting because the default tone keeps sounding until you press a button.
- Runs on the included AC adapter with 3 AA batteries as backup (not included).
- Many NWS offices issue an Ice Storm Warning at about 1/4 inch of ice, though criteria vary by office.
Best for: households in ice storm and blizzard country who want a bedside alarm for overnight warnings.
Avoid if: you need a radio you can carry and recharge by hand; a hand-crank emergency radio fits that job.
Stored power: EcoFlow DELTA 3 Classic
Size stored power for the fridge and small loads, not for heat. EcoFlow rates the DELTA 3 Classic at 1,024 Wh of LFP (lithium iron phosphate) capacity and 1,800 W of output, at 12.1 kg, about 26.7 lb.
- Usable energy: 1,024 Wh x 0.85 inverter efficiency (a common planning figure) = about 870 Wh.
- Fridge: a fridge labeled 385 kWh a year averages 385,000 / 365 = about 1,055 Wh a day, so 870 / 1,055 x 24 h = about 20 hours.
- Space heater: 870 Wh / 1,500 W = 0.58 hours, or about 35 minutes. That is why this kit treats warmth as blankets and layers.
- EcoFlow lists charging at 32°F to 113°F, so keep the station inside the heated part of the house, not in a cold garage.
- UPS switchover of 10 ms per EcoFlow, a full AC charge in about 60 minutes, and a 3-year plus 2-year warranty.
Best for: keeping a fridge, a router, phones, and lanterns going through the first day of an ice storm outage.
Avoid if: you want to run a furnace, a well pump, or electric heat; those need a larger system and, for anything hardwired, a licensed electrician. Our cold weather power station guide covers storage limits.
Warmth: QIO CHUANG Emergency Mylar Blankets, 4-pack
Ready.gov’s additional supply list calls for a sleeping bag or warm blanket for each person. Mylar sheets are a cheap layer to add under those blankets, and they belong in each car kit too.
- Four individually sealed 84 x 55 in sheets, 8.32 oz for the pack, per the listing; the listing’s heat-retention percentage is a seller claim we do not rely on.
- Use them as a layer between bedding, not as the only cover, and keep everyone in one room to share heat.
- Ready.gov treats a body temperature below 95°F as an emergency; shivering, confusion, and drowsiness are warning signs.
Best for: adding a cheap, light layer to every bed and every car during a multi-day outage.
Avoid if: you expect them to replace sleeping bags or wool blankets; they are thin and crinkle, and the house will still cool.
If you plan to add fuel-burning heat, choose an indoor-rated model, follow its manual on ventilation, never run it while sleeping or unattended (CPSC), and store propane cylinders outdoors as Mr. Heater’s manual directs, never inside the house or a garage. Fuel heat makes carbon monoxide, so the CO alarm above comes first. Our heaters for power outages guide compares the options. Never heat the house with a gas stovetop or oven; Ready.gov warns against it.
Fire: Kidde Basic 110 Fire Extinguisher
The NWS winter list names a fire extinguisher and a working smoke alarm, because winter brings more heaters, lanterns, and cooking at odd hours. Kidde rates the Basic 110 (FA110G) at 1-A:10-B:C.
- Per the U.S. Fire Administration, the 1-A part equals about 1.25 gallons of water and 10-B covers about 10 sq ft of flammable liquid fire; C means it is safe on energized electrical equipment.
- 3.9 lb total weight and a 6-year limited warranty, per Kidde.
- Small enough for a kitchen; the USFA advises the largest extinguisher a person can operate safely and comfortably.
Best for: the kitchen and the room where any heater runs.
Avoid if: you want one extinguisher for a garage or workshop; a larger unit suits that space.
Water: Reliance Aqua-Tainer 7 Gallon
Winter water problems come from two places: a well pump that stops with the power, and pipes that freeze. Ready.gov asks for one gallon per person per day for several days.
- Full weight: 7 gal x 8.3 lb per gallon = about 58 lb, plus the container, so fill it where it will stay.
- A rigid jug stored indoors stays above freezing; one left in an unheated garage can freeze solid.
- The CDC says to replace self-filled water every 6 months.
Best for: well homes and houses with plumbing on exterior walls.
Avoid if: no one in the house can lift about 58 lb; smaller jugs are easier to handle.
Cost of Ownership
Most of this kit costs nothing to keep, but four items run on their own clocks.
- CO alarm: replace the unit at its 10-year end-of-life warning, and swap the AA backup batteries when you change your clocks, as the CDC suggests.
- Batteries: 3 AA for the radio, 2 AA for the CO alarm, plus spares for flashlights. NWS asks for extra batteries in every winter kit.
- Power station: top it up at the start of the season and after each storm; it helps only if it is charged.
- Extinguisher: check the pressure gauge as the label directs and replace a disposable unit after any use.
- Water: refill every 6 months, so 2 refills a year x 2 jugs = 4 refills.
How to Size the Kit for Your House
Answer these three questions before you buy, and cross off what your house does not need. Our winter storm prep guide puts the tasks on a timeline.
How many days should the kit cover?
Plan for ice, not snow. The NWS notes that heavy ice brings down trees and utility poles and can disrupt power for days while crews repair it. Ready.gov’s kit asks for water “for several days,” and the CDC sets a 3-day minimum, a reasonable starting point. A household of four for 3 days needs 4 x 1 x 3 = 12 gallons, so two 7-gallon jugs (14 gallons) leave 2 gallons spare. Flushing needs its own supply: at the federal 1.6 gallons per flush maximum, 2 gallons is about 1 flush.
What does the power station have to carry?
Write a 24-hour budget. With about 870 Wh available: a router at 20 W (the top of the 10 to 20 W range on Champion’s wattage chart) x 24 h = 480 Wh, phone charging at 4 phones x 15 Wh = 60 Wh, and two lantern recharges at 16 Wh each = 32 Wh. That totals 572 Wh and leaves about 300 Wh for the fridge, enough for 300 / 1,055 x 24 = about 7 hours. Pick the fridge or the router for the overnight hours, or add a larger station from our home backup guide.
Will anything in the house burn fuel?
If the answer is a portable generator, a propane heater, or a camp stove, add CO alarms before anything else. CPSC says to run a portable generator outdoors only, at least 20 ft from the home, far from windows, doors, and vents, with the exhaust pointed away from the home; never in a garage, porch, or carport. Ready.gov adds that generators and grills belong outdoors and that you should keep generators dry and let them cool before refueling. Follow the maker’s manual and local rules. Our CO safety guide covers placement.
Printable Winter Storm Checklist
- Before the season: CO and smoke alarms with fresh backup batteries on every level and outside sleeping areas, radio programmed for your county, power station charged and stored indoors.
- At the Watch: fill water jugs, charge phones and lanterns, refill prescriptions, top off heating fuel (NWS: refuel before you are empty).
- At the Warning: bring everyone into one or two rooms, set out blankets, keep the fridge closed.
- During the outage: no gas stovetop or oven for heat, fuel equipment outdoors only, check on neighbors.
- Car: jumper cables, sand, flashlight, blankets, water, and snacks, per Ready.gov; see our winter car kit guide.
FAQ
What should be in an ice storm preparedness kit?
Start with the Ready.gov basic kit (water, food, radio, flashlight, first aid, batteries) and add the winter lines: CO alarms with battery backup, a warm blanket or sleeping bag per person, a fire extinguisher, and stored power for the fridge and phones.
Can a power station heat a room in a winter outage?
Not for long. A 1,500 W space heater empties about 870 usable Wh in about 35 minutes (870 / 1,500 x 60). Use stored power for the fridge, lights, and communication, and keep warm with layers in one room.
Where should I keep the winter kit?
Ready.gov asks for a designated place everyone in the house knows; for winter, make it the heated part of the house. Water, batteries, and the power station all do worse in a freezing garage.
Do I need a different kit for the car?
Yes. Ready.gov and the NWS list car items separately: jumper cables, sand or cat litter, a flashlight, blankets, water, snacks, and a full tank of gas. If you are trapped in the car, Ready.gov says to stay inside.
Changelog: October 2026: first published.