CADR, short for clean air delivery rate, is the number on an air cleaner’s box that says how much cleaned air it delivers, measured in cubic feet per minute (cfm). EPA explains that the rating is meant to help you match an air cleaner to the space it serves: the higher the CADR, the more particles the unit can filter and the larger the area it can serve.
Three numbers, three particle sizes
Packaging often lists CADRs for tobacco smoke, dust, and pollen. EPA says these pollutants stand in for small, medium, and large particles, with tobacco smoke representing the smallest. AHAM’s wildfire guidance points to the smoke CADR for smoke events. EPA also notes that the CADR system covers particles only. It says nothing about gases or odors, and EPA adds that filtration supplements source control and ventilation rather than replacing them.
Match CADR to your room
AHAM, the trade group behind the CADR program, gives two rules on its wildfire smoke blog. In normal conditions, smoke CADR should be about two-thirds of the room’s square footage. During a smoke event, it should match the square footage. ENERGY STAR uses the same two-thirds relationship for its sizing chart, which assumes an 8 foot ceiling. EPA’s chart does not state a two-thirds rule, but its minimum CADRs line up with it.
| Room area | Normal days (area x 2/3) | Smoke event (area x 1) |
|---|---|---|
| 150 sq ft | 100 cfm | 150 cfm |
| 300 sq ft | 200 cfm | 300 cfm |
| 450 sq ft | 300 cfm | 450 cfm |
Worked example: a 12 x 15 foot bedroom is 180 sq ft. The everyday target is 180 x 2/3 = 120 cfm of smoke CADR. For a smoke event, aim for 180 cfm. Our best air purifiers for bedrooms and best air purifiers for large rooms guides apply this math to specific models.
Where the rating can mislead
- Highest speed. EPA says CADR is typically measured at the unit’s top fan setting. At a quieter setting you get less airflow than the box shows, and noise depends on fan speed.
- Ceiling height. The charts assume 8 feet. EPA suggests a unit sized for a larger area if your ceilings are higher.
- Open floor plans. EPA advises considering the whole connected space, or using more than one unit.
- “Up to X sq ft” claims. A coverage figure with no CADR beside it cannot be checked against these rules, so compare the CADR instead.
- Homemade filters. A box fan filter has no certified CADR. Research on a four filter build reported roughly 359 cfm, which is a study result, not a rating. See air purifier vs box fan filter.
CADR vs related terms
CADR measures airflow through the cleaner after filtration. A filter’s efficiency rating, such as MERV for HVAC filters, says how well the media captures particles, not how much air a portable unit moves. A strong filter in a weak fan still gives a low CADR. For filter types, see MERV 13 vs HEPA filters, and for the sizing steps in full, what size air purifier do you need.
Changelog: November 2026: first published.