Pick a purifier whose CADR is about 0.65 cfm per square foot of floor area, which is the same as dividing room area by about 1.54. A 200 sq ft bedroom needs a CADR near 130; a 300 sq ft living room, near 195. That is the particle-removal sizing chart ENERGY STAR uses for rooms with 8 ft ceilings. We research and compare agency documents and maker pages, as our how we choose page explains.
The Sizing Formula
Clean air delivery rate (CADR) is the cubic feet of filtered air per minute a unit delivers, and EPA says the higher it is, the more particles the unit removes and the larger the area it can serve. EPA also notes that CADR covers particles only. The ENERGY STAR chart works out to minimum CADR = room area in sq ft x 0.65, so room area = CADR / 0.65, or about CADR x 1.54. The chart is for estimation purposes.
| Room area | Minimum CADR (cfm) |
|---|---|
| 100 sq ft | 65 |
| 200 sq ft | 130 |
| 300 sq ft | 195 |
| 400 sq ft | 260 |
| 500 sq ft | 325 |
| 600 sq ft | 390 |
The chart stops at 600 sq ft. Beyond that you are extrapolating, so treat the result as a rough guide.
Worked Examples
- Bedroom, 12 x 14 ft (168 sq ft): 168 x 0.65 = about 109 cfm. A unit rated 130 or more clears it.
- Living room, 15 x 20 ft (300 sq ft): 300 x 0.65 = 195 cfm. A CADR 200 unit is the nearest fit.
- Open plan, 18 x 30 ft (540 sq ft): 540 x 0.65 = 351 cfm. Two smaller units, one at each end, are one way to reach the total.
Check With Air Changes per Hour
Air changes per hour (ACH) = CADR x 60 / room volume in cu ft. For the 168 sq ft bedroom with an 8 ft ceiling (1,344 cu ft) and a CADR of 130: 130 x 60 / 1,344 = about 5.8 ACH. The ENERGY STAR sizing works out to roughly 4.9 ACH (0.65 x 60 / 8), so a bigger CADR gives you margin.
When to Size Up
- Ceilings above 8 ft: EPA says to choose a higher CADR.
- Open doorways to other rooms, since the unit then serves more than one room.
- Smoke or dust events, when a unit running on its highest speed matters most.
Read the CADR for tobacco smoke, dust and pollen on the box. EPA says the CADR rating system is for particles only, and it has no widely used rating for gas removal. Avoid units that intentionally produce ozone. For how filters differ, see HEPA vs carbon filters, and for a cheap build, how to build a Corsi-Rosenthal box.
Changelog: November 2026: first published.