A carbon monoxide detector is a device with a sensor that measures carbon monoxide (CO), the odorless gas produced when fuel burns, and sounds an alarm when the concentration stays high long enough to reach the trigger points set by the UL 2034 safety standard. Most homes use the self-contained kind, which the fire service calls a CO alarm: sensor, electronics, and siren in one unit on the wall or plugged into an outlet.
Why it matters to a homeowner
You cannot see or smell CO, so an alarm is the only practical warning in a house with a furnace, gas water heater, gas range, fireplace, or attached garage. The CDC reports that more than 400 Americans die each year from unintentional CO poisoning not linked to fires. Outages raise the stakes, because portable generators and fuel-burning heaters come out at the same time; the CPSC says to run a generator outdoors only, at least 20 ft from the home and far from windows, doors, and vents, with the exhaust pointed away from the home, and to keep CO alarms on every level and outside sleeping areas.
How it works
Most current alarms use an electrochemical sensor, in which CO reacts with an electrolyte between electrodes and produces a current the alarm reads as a CO level, according to a Fire Engineering overview of CO alarm technology. Older designs used biomimetic sensors, and some use metal oxide sensors that change electrical resistance in the presence of CO. The alarm does not sound at the first trace of gas. UL 2034 sets time windows by concentration, as summarized by Kidde and BRK:
| CO level | Alarm must sound within |
|---|---|
| 70 ppm | 60 to 240 minutes |
| 150 ppm | 10 to 50 minutes |
| 400 ppm | 4 to 15 minutes |
| 30 ppm steady | Designed not to alarm for 30 days |
The pattern is a dose: higher levels trip the alarm faster. Comparing the latest allowed times, 240 / 15 = 16, so the latest allowed alarm time at 400 ppm is 16 times shorter than at 70 ppm. Our guide to what level of carbon monoxide is dangerous explains the ppm figures.
Carbon monoxide detector vs alarm
In everyday use the two words mean the same thing. In fire codes they differ. A CO alarm has a sensor, controls, and a local sounder, and it is listed to UL 2034. A CO detector, in the strict sense, is a sensor connected to a supervised alarm control unit, and these system-connected devices are listed to UL 2075, UL’s standard for gas and vapor detectors and sensors. Installation rules for both now sit in NFPA 72, which absorbed the withdrawn NFPA 720 starting with its 2019 edition. If you shop at a hardware store, you are buying an alarm.
How to choose one
- Listing: look for UL 2034 on the box, as the CPSC advises.
- Power: battery, plug-in with battery backup, or hardwired with battery backup. A plug-in unit such as the Kidde KN-COB-DP2 runs on house power with AA backup; hardwired units are a job for a licensed electrician.
- Life: Kidde rates CO alarms made since 2013 for 10 years, with a few listed exceptions, while First Alert says most CO alarms last 5 to 7 years. Check the replacement date on the back.
- Display: a digital ppm readout shows low levels that have not yet tripped the alarm.
- Combination units: a smoke and CO alarm saves a mounting spot; see carbon monoxide detector vs smoke detector for when one device covers both jobs.
Where it goes and what to do when it sounds
The CPSC calls for CO alarms on every level of the home and outside separate sleeping areas, kept away from heating vents, kitchens, and spots covered by furniture or drapes; where to put a carbon monoxide detector works through house layouts. A two-story house with a basement and one bedroom hallway needs at least 3 alarms, one per level. When an alarm sounds, the CPSC says not to search for the source: get everyone outside to fresh air, call 911, and account for every person.
For specific models, see our picks for the best carbon monoxide detectors.