A burner swap on most gas grills takes a Phillips screwdriver, a 7/16 inch wrench, and a cool grill with the gas off at the source. Match the replacement to your exact model number, pull the old tubes, set the new ones over the valve orifices, then brush soapy water on every gas connection before you light anything. Weber’s Spirit manual is the source for the steps below; your own manual rules over this page.
Replace or Clean First?
Weber’s manual has a cleaning routine in the same section: look inside each burner with a flashlight, clear it with a straightened wire hanger, check the air shutter openings and valve orifices, and brush the outside with a steel bristle brush. It also says not to enlarge the burner ports. If the ports are open and the tube is sound after cleaning, you may not need a new one. If a tube is rusted through, cracked, or its ports will not clear, replace it.
Get the Right Part
Burner tubes are sold by model series, and tube count and shape differ between grills. Replacement kits are matched to a model or series, and the number of tubes and whether a crossover tube is included depend on the grill. Look up your model number on the data plate and order the kit the maker lists for it. A generic tube that is close in length is not the same part.
| Check | Why |
|---|---|
| Model number on the data plate | Kits are matched to a model or series |
| Number of main burners | A three-burner grill needs three tubes |
| Crossover tube included? | On the Spirit it separates from the burners during removal; check whether your kit includes one |
| Fuel type | Burner parts are made for one fuel, so order the kit for your grill’s fuel |
Steps (Weber Spirit Series Example)
- Weber says the grill must be off and cool. Turn the gas off at the source, meaning the cylinder valve or the natural gas shutoff, before you touch anything.
- Remove the warming rack, cooking grates, and Flavorizer bars.
- Take off the control knobs, remove the control panel screws, pull the igniter button up, and lift the panel out.
- Unhook the manifold wire support clips, then remove the nuts, bolts, and washers that hold the manifold. Set the manifold and valve assembly aside.
- Slide the burner assembly out from under the guide screws and washers, lift and twist it to separate the crossover from the burners, and take the burners out of the cookbox.
- Install the new tubes in reverse order. Weber stresses that the burner openings must sit properly over the valve orifices. Fasten the manifold only after you confirm that alignment.
- Tighten all hardware fully before you use the grill, as the manual says.
Leak Check Before You Light
Weber’s manual says to leak-check the connections with a soap-and-water solution after reinstalling the gas lines. CPSC says the same for propane: open the supply valve fully, brush a soapy solution on the connection, and treat bubbles as a leak. If tightening the connection does not stop it, close the valve and have a qualified professional repair the grill. Full walk-through: how to check a propane grill for leaks. Then light it following how to light a gas grill safely, lid open.
Common Mistakes
- Working on a warm grill. Wait until it is cool, as the manual requires.
- Drilling out clogged ports. Weber says not to enlarge them; replace the tube instead.
- Skipping the orifice alignment. A tube that sits beside the orifice instead of over it is a gas leak path. Recheck before tightening.
- Fixing a gas line yourself. A hose, regulator, or valve that leaks goes to the maker or a qualified technician. Do not improvise parts.
After the Swap
Keep the grill outdoors, clear of the house, deck rails, and overhangs while it runs; CPSC says never use a grill in a garage, breezeway, carport, or porch, because gas grills give off carbon monoxide. Check the rated input on the data plate. As an example, a 40,000 Btu/h grill burns about 40,000 / 91,452 = 0.44 gallons of propane an hour at full input, covered in how long a 20 lb tank lasts.
Changelog: November 2026: first published.