A solar panel produces its rated watts only under lab rating conditions; in real midday sun, a 200 W panel usually delivers about 140 to 170 W, and over a whole day it yields watt-hours, not watts. In Chicago, a 200 W panel tilted toward the sun averages about 200 W x 4.46 peak sun hours x 0.75 real-world derate = about 670 Wh a day across the year.
Two numbers get mixed up here. Watts (W) are the rate of output at one moment, the number a power station’s display shows. Watt-hours (Wh), the size of the tank, are what the panel adds to a battery over a day. This guide covers both, starting with the label.
What the Rating on the Label Means
The rated watts, also called Pmax, are measured at STC, the industry’s standard rating conditions: 1,000 W of sunlight per square meter, a cell temperature of 25°C (77°F), and a set air mass of 1.5. Renogy’s datasheet for its RSP200D 200 W panel spells these out and rates the panel at 200 W, plus or minus 3 percent.
Real panels rarely see both conditions at once. Full 1,000 W per square meter arrives only near solar noon on a clear day, and a dark panel in that sun runs far hotter than 77°F. The same datasheet lists a NOCT (nominal operating cell temperature) of 47°C, plus or minus 2°C, the cell temperature reached under the standard NOCT conditions: a lighter 800 W per square meter, 20°C (68°F) air, and a breeze of 1 meter per second (about 2 mph).
From Rated Watts to Real Watts
The formula: real watts = rated watts x (sunlight / 1,000) x (1 + temperature coefficient x (cell temperature minus 25°C)). The temperature coefficient of Pmax on Renogy’s RSP200D datasheet is -0.37 percent per °C, so every degree of cell heat above 77°F trims about 0.37 percent of output. Check your own panel’s datasheet for its figure.
| Condition | Sunlight (W per sq m) | Cell temperature | Math for a 200 W panel | Output |
|---|---|---|---|---|
| Rating point (STC) | 1,000 | 77°F (25°C) | 200 x 1.0 x 1.0 | 200 W |
| Typical clear day (NOCT conditions) | 800 | 117°F (47°C) | 200 x 0.8 x (1 minus 0.0037 x 22) | about 147 W |
| Hot, still afternoon, full sun | 1,000 | 149°F (65°C), assumed | 200 x 1.0 x (1 minus 0.0037 x 40) | about 170 W |
| Cold, clear winter noon | 1,000 | 50°F (10°C), assumed | 200 x 1.0 x (1 + 0.0037 x 15) | about 211 W |
The NOCT row is the closest thing to a normal good day, which is why a 200 W panel reading in the 140s on a station display is normal rather than a defect. The cold row shows the opposite case: a panel can briefly beat its rating in cold, bright sun, which is also when its voltage climbs. Before that reading reaches the battery, wiring and the station’s charge controller take a few more percent, which is why we plan with a single 0.75 derate rather than chasing each loss.
How Many Watt-Hours a Day, by City
Daily energy = rated watts x peak sun hours x 0.75. A peak sun hour is one hour of 1,000 W per square meter, so a day with 4.46 peak sun hours delivers the same energy as 4.46 hours at the rating point. The sun hours below come from the PVWatts calculator run by the National Laboratory of the Rockies (formerly NREL), for a fixed panel facing south and tilted at the local latitude, using typical-year weather data. They are averages: a given year, month, or yard can come in higher or lower.
| City | Annual avg sun hours | 100 W panel, Wh/day | 200 W panel, Wh/day | 400 W panel, Wh/day | 200 W in December | 200 W in June |
|---|---|---|---|---|---|---|
| Seattle, WA | 3.82 | about 290 | about 570 | about 1,150 | about 240 | about 740 |
| Chicago, IL | 4.46 | about 330 | about 670 | about 1,340 | about 400 | about 810 |
| Minneapolis, MN | 4.66 | about 350 | about 700 | about 1,400 | about 410 | about 790 |
| Boston, MA | 4.72 | about 350 | about 710 | about 1,420 | about 420 | about 760 |
| Atlanta, GA | 5.08 | about 380 | about 760 | about 1,520 | about 580 | about 820 |
The December and June columns use each city’s PVWatts monthly sun hours: Chicago’s 2.66 in December gives 200 x 2.66 x 0.75 = about 400 Wh, and its 5.43 in June gives about 810 Wh. The Department of Energy notes that a mid-latitude city such as Denver gets nearly three times as much solar energy in June as in December, and the tilted-panel figures in the table show the same pattern, from about 1.4 times as much in Atlanta to about 3.1 times in Seattle. Run PVWatts for your own ZIP code before buying; it is free and gives month-by-month figures.
PVWatts itself assumes 14 percent system losses by default for a typical fixed array, which would put the Chicago figure at 200 x 4.46 x 0.86 = about 770 Wh a day. Our 0.75 derate is more conservative because folding panels lie on the ground, heat up, and get moved during the day.
Watts per Square Foot
Panel efficiency sets output per area: 1,000 W per square meter x 25 percent efficiency = 250 W per square meter, and since 1 square meter is about 10.76 sq ft, that is 250 / 10.76 = about 23 W per sq ft of cell area. Frames, hinges, and gaps between folding sections lower the figure for the whole panel. Renogy’s rigid RSP200D, at 19.2 percent module efficiency and 58.7 x 27.5 in, works out to 200 W / 11.2 sq ft = about 18 W per sq ft. So a balcony railing with 10 sq ft of direct sun can host roughly 180 to 230 W of panel, depending on efficiency.
How Fast a Panel Charges a Battery
Charging speed in watts is the smaller of what the panel makes and what the station accepts. A 200 W panel at about 147 W of real output adds roughly 147 Wh to a battery per hour of good sun, minus a few percent in the charge controller. A 200 W folding panel like Renogy’s can top up phones and a router battery quickly, while a 1,000 Wh station takes most of a sunny day. For full charge-time tables, see how long it takes to charge a power station with solar.
Mistakes That Make a Panel Look Broken
- Laying it flat in winter. PVWatts puts Minneapolis in December at 2.75 sun hours tilted but only 1.30 flat, so the flat panel collects 1.30 / 2.75 = about 47 percent as much.
- Partial shade. A shadow across a few cells can cut the whole panel’s output by much more than the shaded share of its area.
- Reading the display at 9 a.m. Sunlight is weaker away from solar noon, so early readings run well under the rating.
- Hitting the station’s current limit. Some stations cap amps at low voltage, which holds a 20 V panel below its rating no matter how strong the sun.
- Comparing a hot panel to its label. On a summer afternoon, the temperature math alone takes about 15 percent off at a 149°F cell temperature.
To turn these numbers into a purchase, start with how to choose a solar panel for a power station, then compare models in our guide to the best solar panels for power stations. For what one watt-hour buys you in runtime, see our watt-hour explainer.
Changelog: November 2026: first published.