Run a basement dehumidifier in winter only when a hygrometer shows the basement above about 50 percent relative humidity and the air there stays at 65°F or warmer. ENERGY STAR warns that frost can form on a dehumidifier’s coils below 65°F, and in an unheated basement the cold outdoor air seeping in is usually dry enough to pull humidity down on its own. A heated, finished basement with a known moisture source is the main exception.

Check two numbers first

Put a digital hygrometer in the basement for three or four days before you decide anything. It reads relative humidity (RH), the share of moisture the air holds compared with the most it could hold at that temperature, and most models also read temperature. Those two readings answer the question.

Basement temperatureBasement RHWhat to do
AnyBelow 40%Turn the dehumidifier off for the season and drain it
65°F or warmer40% to 50%Leave it on with the humidistat at 50%; it will rarely start
65°F or warmerAbove 50%Run it, and look for a moisture source such as a damp wall or a dryer vent
Below 65°FAbove 50%Expect coil frost on a standard compressor unit; see the cold basement options below
Below 41°FAnyMany compressor units, GE’s among them, are not meant to operate here; switch it off

ENERGY STAR puts the optimum range for a building at 30 to 50 percent RH and suggests 30 to 40 percent in cold weather to limit condensation on windows. Our page on the ideal basement humidity level explains where those limits come from.

Why winter air dries most basements

Cold air holds very little water, so when it leaks into the basement and warms up, its RH falls sharply. You can work this out from saturation vapor pressure, the most vapor air can hold at a given temperature, using standard psychrometric values: about 0.103 inHg at 20°F, 0.165 inHg at 30°F, 0.435 inHg at 55°F, and 0.521 inHg at 60°F.

  • Cold, clear January day: outdoor air at 20°F and 70% RH warms to 60°F in the basement. New RH = 70% x (0.103 / 0.521) = about 14%.
  • Raw, damp day near freezing: outdoor air at 30°F and 80% RH warms to 55°F. New RH = 80% x (0.165 / 0.435) = about 30%.

Both results land at or below the bottom of the ENERGY STAR range before any machine runs. That is why many owners who run a dehumidifier hard in July find the bucket nearly empty by January. The summer case runs the other way, which our humidity page works through with the same method.

Why a dehumidifier freezes up in a cold basement

A compressor dehumidifier pulls moisture out by running air over coils colder than the air’s dew point. When the room itself is cool, those coils drop below 32°F and the water they collect turns to frost. ENERGY STAR says this can start once the air falls below 65°F, and that frost can make the compressor cycle without removing moisture.

Manufacturers handle this in two ways. GE’s owner manuals for several models describe an automatic defrost cycle, where the compressor stops and the fan keeps running until the coil clears, and they tell owners to keep the unit where the temperature stays at or above 41°F. Units with an anti-frost sensor, ENERGY STAR notes, shut off on their own when the air gets too cold. Either way, a unit that spends hours defrosting removes little water while it still draws power.

Rated capacity tells you little here. The current Department of Energy rating for portable dehumidifiers is measured at 65°F and 60 percent RH, so the pints on the box describe a mild basement, not a 50°F one. Our explainer on dehumidifier pint ratings covers that rating in detail.

If the dehumidifier keeps freezing up

  1. Read the hygrometer first. If RH is already under 50 percent, the fix is to switch the unit off, not to keep it running.
  2. Turn it off and let it thaw. ENERGY STAR advises switching the unit off and letting the frost melt before restarting it.
  3. Clean the filter. A clogged filter cuts airflow across the coils, so follow the cleaning interval in the manual.
  4. Check the low limit in the manual. If the basement sits below the stated minimum, the unit is the wrong tool for winter there.

Options for a cold, damp basement

Some basements stay damp in winter because water comes through the walls or floor, not through the air. Handle the water first, then the air.

  • Fix the source. Check gutters, downspouts, and the grade around the foundation, and confirm the dryer vents outdoors. ENERGY STAR notes that reducing sources of moisture can reduce your need for dehumidification.
  • Choose a model rated for lower temperatures. ENERGY STAR suggests this for spaces that often sit under 65°F. Desiccant dehumidifiers, which absorb moisture rather than condensing it on cold coils, are also marketed for cooler spaces; compare the operating range on each spec sheet.
  • Warm the space slightly. If the basement is part of the heated envelope, holding it at 65°F or above lets a standard unit work as rated.

Our guide to the best dehumidifiers for basements lists each model’s low operating temperature where the maker publishes it.

Winter or summer: when the dehumidifier earns its keep

Summer is the main season for most basements. Warm, humid outdoor air cools as it enters, and its RH rises instead of falling. In winter, the useful jobs for the basement are different: keep pipes above freezing, watch for leaks, and keep an eye on the hygrometer.

A cold snap is when supply lines in an unheated basement are most likely to freeze and split, so this is a good season to set a leak sensor at the basement’s low point. Our guides to the best water leak detectors and how to keep pipes from freezing cover both jobs.

Common mistakes

  • Leaving the humidistat on continuous from summer through winter.
  • Judging dampness by smell or feel instead of a hygrometer reading.
  • Running a compressor unit in a basement below the manual’s minimum temperature.
  • Leaving water in the bucket or hose through a cold spell when the unit is off for the season.
  • Treating a frosted coil as a broken unit before checking the room temperature.

Winter checklist

  • Hygrometer in the basement, read for three or four days
  • Unit off if RH stays under 40 to 50 percent
  • Filter cleaned before the unit goes back on
  • Manual checked for the minimum operating temperature
  • Bucket emptied and dried if the unit is stored
  • Leak sensor at the basement low point