For most desktop PCs, the CyberPower CP1500PFCLCD is the safe pick: it is rated 1,000 W, which leaves room for a gaming rig, and it outputs a sine wave that CyberPower pairs with active PFC power supplies. If your PC and monitor draw under about 260 W and you only want time to save and shut down, the APC BE600M1 does that with a smaller unit.
Quick Comparison
| Model | VA / W | Output waveform | Battery | Battery outlets | Best for |
|---|---|---|---|---|---|
| CyberPower CP1500PFCLCD | 1500 / 1000 | Sine wave | 2 x 12 V 9 Ah (216 Wh) | 6 | Gaming PC with active PFC supply |
| CyberPower CP1500AVRLCD3 | 1500 / 900 | Simulated sine, AVR | 2 x 12 V 9 Ah (216 Wh) | 6 | Mid-range PC where voltage dips are common |
| APC Back-UPS BE600M1 | 600 / 330 | Stepped sine | 12 V 6.5 Ah (78 Wh) | 5 | Office PC and one monitor |
| CyberPower SL700U | 700 / 370 | Simulated sine | 12 V 5.5 Ah (66 Wh) | 5 | Small, wall-mountable desk setup |
Battery energy is volts x amp-hours x number of batteries. Specs come from CyberPower and Schneider Electric (APC) datasheets and product listings.
How We Chose
We ranked by watt headroom first, then output waveform, then stored battery energy and whether you can replace the battery. We research and compare; we do not run our own product trials. Yard & Grid Score comes from verified buyer ratings (how we choose). We left out the APC BE425M and CyberPower ST425 (about 260 W class, too small for most towers) and the OR500LCDRM1U, a rack-mount unit. For modem and router backup, see our network UPS guide.
1. CyberPower CP1500PFCLCD
- 1500 VA / 1000 W line-interactive with sine wave output. CyberPower describes it as suited to active PFC power supplies, which many modern gaming PSUs use.
- CyberPower’s datasheet lists 10 minutes at half load and 2.5 minutes at full load, and a user-replaceable battery.
- Three-year warranty including batteries, per CyberPower’s datasheet, which gives 24.9 lb.
Best for: a gaming PC, a workstation, or any rig whose PSU manual asks for a sine wave.
Avoid if: you have a basic office PC and a short desk; the size and weight are more than you need.
2. CyberPower CP1500AVRLCD3
- 1500 VA / 900 W with automatic voltage regulation, which corrects minor sags without switching to battery, so the battery wears less where dips are frequent.
- Simulated sine output, so check your PSU manual before pairing it with an active PFC supply.
- Same 216 Wh of battery as the PFC model; the datasheet lists a user-replaceable battery (RB1290X2E) and 23.8 lb.
Best for: a mid-range PC plus monitor and router on one unit.
Avoid if: your PSU manual requires a sine wave.
3. APC Back-UPS BE600M1
- 600 VA / 330 W, 7.69 lb. Schneider’s datasheet lists a 6 ms typical (10 ms maximum) transfer time and a user-replaceable 12 V 6.5 Ah battery (APCRBC154).
- The APC listing gives 23 minutes at 100 W: 100 x 23 / 60 = about 38 Wh delivered from the 78 Wh stored.
- Warranty is 3 years on the unit and 1 year on the battery; typical battery life is 3 to 5 years.
Best for: a low-power desktop and one monitor.
Avoid if: your PC pulls more than about 260 W under load (see the sizing math below).
4. CyberPower SL700U
- 700 VA / 370 W standby unit, 12.76 x 5.4 x 2.76 in, 6.77 lb, with keyhole slots for wall mounting.
- Smallest battery here at 66 Wh, so expect a short ride-through; the datasheet’s typical applications list routers and modems.
- Three-year warranty; CyberPower’s listing says it includes the battery.
Best for: a compact PC where desk space is tight.
Avoid if: you want to replace the battery yourself; the datasheet does not list it as user-replaceable.
Cost of ownership
The recurring cost is the sealed lead-acid battery. Schneider puts typical life at 3 to 5 years, and CyberPower’s datasheets and listings show 3 years of coverage including the battery. Budget a replacement battery about every 3 to 5 years. Higher-wattage models cost more up front but share the same battery chemistry, so the unit price tells you little about battery wear.
Sizing your UPS
Add the watts of everything on the battery outlets, then divide by 0.8. The 0.8 is a common planning margin that keeps the load below the rating. Example, with illustrative numbers: a PC drawing 250 W under load plus a 30 W monitor is 280 W, and 280 / 0.8 = 350 W. That rules out the 330 W BE600M1, makes the 370 W SL700U a tight fit, and fits the 900 W and 1,000 W units comfortably.
Runtime does not scale in a straight line. The 216 Wh battery at 500 W, with 0.85 for inverter loss, gives 216 x 0.85 / 500 = about 22 minutes on paper, yet CyberPower’s datasheet lists 10 minutes at half load. Use the maker’s figure, and treat the UPS as time to save and shut down, not to keep gaming. Leave a space heater (1,500 W is typical) or laser printer off the battery outlets; their draw is beyond what these units are meant to supply.
If you want hours rather than minutes, a power station with UPS mode is the better tool; see power stations with UPS mode. For the basics, read what a UPS battery backup is.
FAQ
Does my gaming PC need a sine wave UPS?
CyberPower positions its sine wave model for active PFC supplies and its simulated sine units for general workstations. Read your PSU manual; if it asks for a sine wave, choose the CP1500PFCLCD.
What size UPS do I need for a desktop?
Add your load in watts and divide by 0.8, as in the sizing example above. Size by the watt rating, not VA alone.
How long will a UPS run my PC?
Usually minutes. The CP1500PFCLCD is listed at 10 minutes at half load. Plan for a calm shutdown, not extended use.
Changelog: November 2026: first published.