Heat tape, heat cable, and heat trace all describe an electric cable that runs along a water pipe and warms it so the water does not freeze. “Heat tape” is the hardware-store name for a short plug-in kit, “heat cable” is the generic product name makers print on the box, and “heat trace” (electric heat tracing) is the engineering term for a designed system of cable, controls, insulation, and circuit used in commercial and industrial buildings. For a homeowner, the label matters far less than the cable type inside the package: constant wattage or self-regulating.

Who uses each term

TermWho says itWhat it usually meansTypical example
Heat tapeHomeowners, retailersA plug-in pipe cable sold in fixed lengths, often with a built-in thermostatHEATIT 6 ft kit, 7 W per foot, constant wattage
Heat cableManufacturers, spec sheetsThe heating element itself, constant wattage or self-regulatingEasyHeat AHB, 7 W per foot; EasyHeat SR, 3, 5, or 8 W per foot at 50°F
Heat traceEngineers, commercial specsA full system: cable, controller, insulation, and a dedicated circuit, designed to IEEE 515 (industrial) or IEEE 515.1 (commercial)Freeze protection for sprinkler piping, roof and gutter deicing

One twist: in industrial catalogs, “heat tape” can mean something else entirely. A 2015 NIH technical bulletin lists heat tape as a separate class of electric heat tracing for high-density, high-temperature heating, next to self-regulating, constant wattage, and mineral insulated cable. If a search turns up a lab heating tape rated for hundreds of degrees, it is the wrong product for a crawl space pipe.

The difference that matters: constant wattage vs self-regulating

A constant wattage cable puts out the same heat per foot whenever its thermostat is on. EasyHeat rates its AHB cable at 7 W per foot, switching on at 38°F or below and off at 45°F and above. Because it cannot lower its own output, it must never cross or overlap itself.

A self-regulating cable has a conductive core that lowers its output as the pipe warms and raises it as the pipe cools. EasyHeat rates its SR cable at 3, 5, or 8 W per foot, measured at 50°F. Some self-regulating makers allow extra wraps at valves and meter bodies, which is why it is the usual choice for runs with fittings.

Run the numbers on a 12 ft crawl space line. A constant wattage cable at 7 W per foot draws 12 x 7 = 84 W while it is on; if the thermostat keeps it on for 12 hours on a hard night, that is 84 x 12 = about 1,000 Wh, or about 1 kWh. A 3 W per foot self-regulating cable on the same pipe draws about 12 x 3 = 36 W at 50°F, and more as the pipe gets colder, so read that figure as the rating point, not a maximum.

For a typical plug-in job, a self-regulating cable such as the HEATIT 30 ft self-regulating heat cable is the easier one to install correctly. Our best heat tape for pipes guide compares both types, and heat tape vs pipe insulation explains when foam alone is enough.

Rules that apply whatever the box says

CPSC’s heat tape guidance dates from releases in 1989 and 1996, and it still reads as a sound checklist:

  • Buy cable certified by UL, CSA, or Factory Mutual (CPSC, 1996).
  • Plug it into a grounded three-prong outlet protected by a GFCI (CPSC, 1996); EasyHeat also requires GFCI protection for AHB cable.
  • Inspect it every fall before the first freeze (CPSC, 1989), and at least once a year (CPSC, 1996).
  • Do not overlap a cable unless the maker permits it (CPSC, 1989).
  • Do not cover it with foam or vinyl insulation (CPSC, 1996). Cover it only with non-flammable insulation, and only if the maker allows it, never thicker than the instructions recommend (CPSC, 1989).

When you need heat trace, not heat tape

A plug-in kit is the right fit for a short, reachable pipe near an outlet. Avoid if the run is longer than the kits sold, needs a hardwired circuit, protects fire sprinkler piping, or sits inside a wall, floor, or ceiling. Those jobs are heat trace work: a designed system that a licensed electrician sizes and installs to code.

Every version of this product needs electricity. When the power goes out on a cold night, the cable goes cold with it, so pair it with the steps in how to keep pipes from freezing and a backup heat plan from our best heaters for power outages guide.