A Corsi-Rosenthal box is a box fan with MERV 13 furnace filters taped around it into a cube, so the fan pulls room air through the filters. Four or five filters, tape, and a fan built in 2012 or later are the core of it. EPA treats it as a stopgap for when a commercial air cleaner of known performance is not available or affordable, not a permanent replacement. We research and compare agency documents and maker pages, as our how we choose page explains.

What You Need

  • A box fan made in 2012 or later. EPA says fans built before 2012 may pose fire risks, and it suggests a UL or ETL safety marking.
  • MERV 13 or higher filters sized to your fan. EPA advises a filter that matches the fan, and says designs with more filters generally work better.
  • Duct tape, plus cardboard if you want a shroud. Clean Air Crew describes a cardboard shroud sized to the fan as optional.

Build Steps

Clean Air Crew, the group behind the design, gives photo captions rather than numbered steps, so this order is a summary of its pages and EPA guidance. Typical builds use five 2 inch filters (its page lists three 20 x 20 x 2 and two 16 x 20 x 2), or four filters of the same size for a simpler cube.

  • Check the fan label for a 2012 or later date and for a fused plug and thermal cutoff, and compare the model to the CPSC recall notice (see below).
  • Stand the filters up as the sides of a box. Point the airflow arrows on every filter inward, toward the fan.
  • Tape every seam. EPA says to get a good seal between the fan and filter, so leaks around the edges undercut the whole build.
  • Put the fan on top (Clean Air Crew shows top-fan and side-fan versions), and close any open face or gap with cardboard and tape. Air then enters through the filters and leaves through the fan.
  • Run it on high, near where people sit, with the room door closed. EPA says to run a DIY cleaner as often as possible on the highest fan speed.

Fan Safety Rules

EPA, working with UL, looked at five commercial box fans with one filter each and found no fire or burn risk in the conditions examined, but it still points to newer fans. If you must use a fan built before 2012, EPA says not to leave it unattended or use it while sleeping. Its guidance says to follow the fan maker’s instructions, including no extension cord, and to keep working smoke detectors in the home. A 2011 CPSC recall covered about 4.8 million Lasko box fans (models 3720, 3723, 3733 and Galaxy 4733, with 2002 to 2004 date stamps) for a motor electrical failure that could start a fire. As a general precaution, we would not leave any box fan running while you are out or asleep.

What to Expect

A Penn State Extension article reports about 359 cfm of clean air delivery for a four-filter MERV 13 box in a study, which is one study’s figure and not a certified rating. Example: 359 x 60 / 1,440 cu ft (a 12 x 15 ft room, 8 ft ceiling) is about 15 air changes per hour. The same article reports MERV 13 filters improved cleaning by about 71% over MERV 8. EPA adds that each DIY unit may perform differently, even when you rebuild the same one with new filters, and its findings are about particles such as smoke; its VOC research is still ongoing.

Swap a filter when it looks heavily soiled or starts to release smoke odors, and more often during heavy smoke, per EPA. EPA says filters loaded with smoke or dust were almost completely ineffective. For a purchased unit instead, see what size air purifier you need. For the full comparison, read air purifier vs box fan filter and MERV 13 vs HEPA.