Put your first carbon monoxide detector in the hallway outside the bedrooms, then add one on every level of the home, including the basement, and keep each one at least 15 ft from the furnace, water heater, and other fuel-burning appliances. That order follows NFPA and CPSC guidance on sleeping areas and levels, and the 15 ft spacing comes from Kidde’s placement advice.

Placement in priority order

  1. Outside each separate sleeping area. NFPA guidance calls for a CO alarm in a central spot just outside each separate sleeping area, near the bedrooms. Kidde says that if you own only one CO alarm, this hallway is where it goes, because you are most at risk while asleep and need to hear it.
  2. On every level, including the basement. The CPSC recommends battery-operated or battery-backup CO alarms on every level of the home and outside sleeping areas. First Alert recommends the top of the basement stairs for the basement unit.
  3. Inside bedrooms, for added coverage. First Alert also recommends alarms inside each bedroom, which helps when bedroom doors stay closed at night.
  4. Anywhere your local code adds. Some states and towns require more, often tied to fuel-burning appliances or attached garages, so check before you buy.

High or low on the wall?

Follow the manual, because CO has no strong pull up or down. Carbon monoxide’s molecular weight is about 28.0, and dry air averages about 29.0, so CO is only 28.0 / 29.0 = about 0.97 times as dense as air. It mixes into room air rather than settling on the floor or collecting at the ceiling, which is why the rule is “where the manufacturer says,” not a fixed height.

In practice, NFPA’s alarm code points to the wall, ceiling, or other location in the unit’s installation instructions. The CPSC notes that alarms can be plugged into an outlet or mounted high on a wall. A plug-in unit at outlet height is fine when it is designed for that, as long as furniture and curtains do not cover it.

Smoke alarms are different: smoke rises, so they belong on the ceiling or high on the wall. That is one reason a combination smoke and CO alarm usually goes on the ceiling. Our comparison of carbon monoxide detectors vs smoke detectors covers where the two sets of rules overlap.

Upstairs or downstairs?

Both. “Every level” is the guidance from the CPSC and NFPA, and the basement level matters most in many homes because that is where the furnace and water heater sit. Here is how the rule plays out in common US house layouts.

HomeWhere the alarms goMinimum count
One-floor apartment, bedrooms off one hallwayHallway outside the bedrooms1
Ranch house, bedrooms at opposite endsOutside each bedroom wing2
Ranch house with a basement furnaceBedroom hallway, top of the basement stairs2
Two-story house with basement, bedrooms upstairsUpstairs hallway, main floor, top of the basement stairs3
Split-level with four short levels, bedrooms on the top levelBedroom hallway plus one on each of the other three levels4

The count formula is simple: alarms = number of levels + extra sleeping areas on a level that already has one. The ranch with bedrooms at opposite ends shows the second term: 1 level + 1 extra sleeping area = 2.

Where not to put one

SpotWhySource
Kitchens and directly above fuel-burning appliancesCPSC lists these spots to avoid; alarms close to burners are more prone to nuisance alarms, First Alert notesCPSC
Within 15 ft of a furnace, water heater, or rangeKidde advises at least 15 ft; First Alert advises 15 to 20 ftKidde, First Alert
Next to heating or cooling ventsCPSC lists heating vents as a spot to avoidCPSC
Behind furniture or curtainsA covered sensor cannot sample room airCPSC, Kidde
Bathrooms and next to showersFirst Alert suggests keeping alarms about 10 ft from humidity sources such as showersFirst Alert
Places outside the manual’s temperature rangeUnheated spaces can fall outside the rated rangeManufacturer manual

The 15 ft rule is easy to check with a tape measure. In a basement where the furnace and water heater stand together at one end and the stairs sit 25 ft away, an alarm at the top of the stairs clears the spacing with 25 minus 15 = 10 ft to spare. If the stairs land right beside the furnace, move the alarm along the hallway at the top until it measures 15 ft or more from the appliance.

Common mistakes

  • Putting the only CO alarm in the kitchen or next to the furnace instead of outside the bedrooms.
  • Skipping the basement because nobody sleeps there.
  • Using a plug-in alarm with no battery backup, which goes dark in an outage. Our guide to carbon monoxide safety during power outages covers why that matters.
  • Moving a plug-in unit from room to room. Kidde advises installing the alarm and leaving it in one place.
  • Assuming a smoke alarm on the ceiling also covers CO when the label does not say combination.

Placement only helps while the sensor is still within its rated life; our page on how long carbon monoxide detectors last covers dates and end-of-life signals. For models, see the best carbon monoxide detectors, and add spare alarm batteries to the list in our home emergency kit guide.

Placement checklist

  • One alarm in the hallway outside each sleeping area
  • One alarm on every level, basement included
  • Each alarm 15 ft or more from fuel-burning appliances
  • None in the kitchen, bathroom, or next to an air vent
  • Nothing covering any alarm
  • Mounting height taken from each unit’s manual

Changelog: November 2026: first published.