Close up the skirting first, then wrap or heat the exposed supply lines, then keep the heat on and a faucet dripping during hard cold. In a mobile or manufactured home the water lines usually run under the floor, and the skirting and belly cover are the main barrier between those pipes and the wind. Fix the barrier before you add any heating hardware.

Step 1: Seal the Skirting and Belly

Walk the whole perimeter in fall and look for missing panels, gaps at corners, and the access door. A gap that lets wind reach a supply line can be enough to freeze it, and the Red Cross lists pipes in unheated crawl spaces and along poorly insulated outside walls among those that freeze most often. Texas’s manufactured housing regulator (TDHCA) notes that skirting protects the plumbing, heating, and electrical systems under the home. Patch holes in the panels, but keep the skirting vents clear: TDHCA warns that vents blocked by snow or ice for long periods can trap moisture under the home. Look up at the underbelly too: a torn or sagging belly cover (bottom board) leaves the pipes bare. TDHCA says tears should be repaired with special purpose tape and proper fasteners, so a crew that works on manufactured homes is a better call than stuffing material in yourself.

Step 2: Insulate Every Exposed Line

Sleeve each exposed supply line, plus the point where the water line enters the home and any section that rises through the floor near an outside wall. Foam sleeves work on straight runs. Insulation slows heat loss but does not make heat, so in a long hard freeze it only buys time. That is why the Red Cross suggests UL-listed heat tape or heat cable as an option for exposed water pipes. Our comparison of heat tape vs pipe insulation explains where each one fits.

Step 3: Use Heat Tape Only the Way the Maker Says

Buy a cable that carries a UL, CSA, ETL, or FM mark on the cable itself as well as the plug, and follow its instructions line by line. The CPSC’s heat tape releases from 1989 and 1996 warn against overlapped cable, the wrong insulation on top, and old or damaged tape. Do not build your own heating setup from other cable or wire. Our heat tape guide lists the maker rules for each cable we reviewed, and this explainer sorts out the labels.

CheckWhat to do
Cable typeSelf-regulating if the line has a valve or fitting that needs extra wraps; constant wattage cable must never cross itself
Pipe materialRead the pipe label and the cable’s list of approved materials; call a plumber if the pipe is unmarked
Insulation over the cableOnly the type and thickness the manual names; the CPSC’s 1996 release says not to use foam or vinyl insulation that could catch fire from a failing heat tape
PowerGrounded GFCI outlet; follow the manual on extension cords, and have an electrician add an outlet near the pipe if needed
Yearly checkReplace cable with a cracked, charred, or discolored jacket

For a long supply line, a self-regulating cable like the HEATIT 30 ft model is one option. The Amazon listing gives it 3 W per foot with a built-in thermostat that turns on at 38°F and off at 50°F, and says the whole cable is ETL certified with a UL certified plug. Read the included instructions before you buy, because they decide how you can wrap and cover it.

HEATIT 30ft Self-Regulating Heat Tape for Water Pipe Freeze Protection 3W

Prime HEATIT 30ft Self-Regulating Heat Tape for Water

Pipe Heat Cables
HEATIT
amazon.com
★ ★ ★ ★ ★
4.5 (4.4K reviews)
In Stock
$34.99
Updated: October 26, 2026
Price as of Oct 26, 2026. We earn from qualifying purchases.

As an Amazon Associate we earn from qualifying purchases. Product prices and availability are accurate as of the date/time indicated.

What Heat Tape Costs to Run

Watts per foot x feet x hours on x days / 1,000 = kWh. For the 30 ft cable at its full 3 W per foot, that is 90 W. Assume the thermostat keeps it on 12 hours a day for 60 cold days: 90 x 12 x 60 / 1,000 = about 65 kWh, and at 18 cents per kWh (EIA put the U.S. residential average at 18.16 cents for August 2026), 65 x 0.18 = about 12 dollars for the winter. Self-regulating cable draws less as the pipe warms, so treat this as a ceiling. At 120 V the draw is 90 / 120 = 0.75 A.

Step 4: Heat and Drip on the Coldest Nights

Keep the thermostat at one setting day and night, and never below 55°F if you leave, as the Red Cross advises. Open the cabinet doors on outside walls. Let a cold faucet on an exposed line run at a trickle. Check the volume first: a trickle that fills 1 cup in 4 minutes is 0.25 x 60 x 12 / 16 = about 11 gallons over 12 hours. Our guide on dripping faucets covers which ones to choose. For the full home list, see how to keep pipes from freezing.

Common Mistakes

  • Counting on heat tape during an outage. It stops with the power, so know where your main shutoff is and how to drain the lines.
  • Covering heat tape with whatever insulation is on hand.
  • Leaving a skirting gap “for now.” One open corner can aim wind at the pipe.
  • Setting the thermostat back at night in a freeze.

If a line stops running, do not thaw it with an open flame. Follow our steps for thawing frozen pipes safely. We research and compare; we do not run our own product trials. See how we choose.

Changelog: November 2026: first published.